The Pt100 RTD handheld thermometer is a high accuracy device, capable of reading temperatures up to 850.0°C (1562.0 °F).
Standard Features:
- Min./Max. Memory: Memorising of max. and min. values.
- Hold Function: Freeze the current display values at the push of a button.
- Auto-Off-Function: 1…120min (can also be deactivated).
- Offset and Slope Input: offset and scale factor can be entered digitally
GMH3570 Additional Features:
Alarm: 3 different alarm settings:
- Off: alarm function not activated
- On: visual alarm via display, integrated buzzer and interface
- No Sound: alarm via display and interface
Min./Max. Alarm: the measuring value is constantly monitored and the alarm triggered if it goes
outside the min./max. limits set.
Logger functions:
- Real-time clock: clock with date and year
- Manual: 99 data sets (data recall via keyboard or interface)
- Cycle: 16,200 data sets (data recall via interface)
- Adjustable cycle time: 1sec. … 1h. Logger start and stop via the keyboard or interface.
- Easy to use read-out and display software (GSOFT3050) available as an option.
Specifications
- Measuring Range: -199.99 … +199.99°C or -200.0 … + 850.0°C (-199.99 … +199.99°F or -328.0 … +1562.0 °F)
- Resolution: 0.01°C or 0.1°C; 0.01°F or 0.1 °F
- Auto-Range: automatically or manually select the measuring range.
- Accuracy (±1 digit) (@ 25°C):
- ≤ ± 0.03°C for -199.99 to +199.99°C range
- ≤ ± 0.1°C for -200.0 to +850.0°C range
- GMH3750 additionally supports a 50-point user defined curve.
- Temperature Drift: ≤ 0.002 °C/K
- Probe: Pt100, 4-wire, DIN EN 60751. Probe connection via 4-pin miniature DIN-plug
- Operating Temperature: -25 to +50°C
- Relative Humidity: 0 to +95%RH. (non-condensing)
- Storage Temperature: -25 to +70°C
- Display: two 4½ digit LCDs (12.4mm or 7mm high), with additional symbols.
- Keypad: 6 membrane keys
- Output: 3.5 mm stereo jack socket, choice between serial interface or analogue output
- Serial Interface: direct connection to RS232 or USB interface of a PC via electrically isolated interface adapter GRS3100/USB3100.
- Analogue Output: 0…1V, adjustable (resolution 13bit, accuracy 0.05% at nom. temp.)
- Power Supply: 9V-battery (included) as well as additional d.c. connector for external 10.5- 12V direct voltage supply. (suitable power supply: GMH37XX-PSU)
- Low Battery Warning: ‘ bAt ‘
- Power Consumption: approx. 1 mA
- Dimensions: 142 x 71 x 26 mm (H x W x D)
- Housing: Impact resistant ABS plastic housing, membrane keypad. Front face IP65, integral stand/belt-clip.
- Weight: approx. 155 g
The Pt100 RTD handheld thermometer is a high accuracy device, capable of reading temperatures up to 850.0°C (1562.0 °F).
Standard Features:
- Min./Max. Memory: Memorising of max. and min. values.
- Hold Function: Freeze the current display values at the push of a button.
- Auto-Off-Function: 1…120min (can also be deactivated).
- Offset and Slope Input: offset and scale factor can be entered digitally
GMH3570 Additional Features:
Alarm: 3 different alarm settings:
- Off: alarm function not activated
- On: visual alarm via display, integrated buzzer and interface
- No Sound: alarm via display and interface
Min./Max. Alarm: the measuring value is constantly monitored and the alarm triggered if it goes
outside the min./max. limits set.
Logger functions:
- Real-time clock: clock with date and year
- Manual: 99 data sets (data recall via keyboard or interface)
- Cycle: 16,200 data sets (data recall via interface)
- Adjustable cycle time: 1sec. … 1h. Logger start and stop via the keyboard or interface.
- Easy to use read-out and display software (GSOFT3050) available as an option.
Specifications
- Measuring Range: -199.99 … +199.99°C or -200.0 … + 850.0°C (-199.99 … +199.99°F or -328.0 … +1562.0 °F)
- Resolution: 0.01°C or 0.1°C; 0.01°F or 0.1 °F
- Auto-Range: automatically or manually select the measuring range.
- Accuracy (±1 digit) (@ 25°C):
- ≤ ± 0.03°C for -199.99 to +199.99°C range
- ≤ ± 0.1°C for -200.0 to +850.0°C range
- GMH3750 additionally supports a 50-point user defined curve.
- Temperature Drift: ≤ 0.002 °C/K
- Probe: Pt100, 4-wire, DIN EN 60751. Probe connection via 4-pin miniature DIN-plug
- Operating Temperature: -25 to +50°C
- Relative Humidity: 0 to +95%RH. (non-condensing)
- Storage Temperature: -25 to +70°C
- Display: two 4½ digit LCDs (12.4mm or 7mm high), with additional symbols.
- Keypad: 6 membrane keys
- Output: 3.5 mm stereo jack socket, choice between serial interface or analogue output
- Serial Interface: direct connection to RS232 or USB interface of a PC via electrically isolated interface adapter GRS3100/USB3100.
- Analogue Output: 0…1V, adjustable (resolution 13bit, accuracy 0.05% at nom. temp.)
- Power Supply: 9V-battery (included) as well as additional d.c. connector for external 10.5- 12V direct voltage supply. (suitable power supply: GMH37XX-PSU)
- Low Battery Warning: ‘ bAt ‘
- Power Consumption: approx. 1 mA
- Dimensions: 142 x 71 x 26 mm (H x W x D)
- Housing: Impact resistant ABS plastic housing, membrane keypad. Front face IP65, integral stand/belt-clip.
- Weight: approx. 155 g