Portable Oxygen Analyser

GAB-1700
Download PDFs:
PDF Icon

The OMEGA GAB-1700 oxygen analyzer has been specifically designed to meet the demanding needs of field and laboratory analysts, light industrial users and others who require fast, accurate and reliable analysis of common gas mixtures. This compact, portable and easy to use instrument is based upon a non-depleting, component specific measurement technique (magnetodynamic paramagnetic) for long life and minimal running costs, avoiding the problems associated with electrochemical or other less robust methods of analysis.

Specifications

  • Gases Measured Oxygen (O2) Sensors Oxygen
  • Technology: Paramagnetic
  • Variant: Industrial
  • Full Scale Range (FSR): 0 to 100% O2
  • Minimum Output Range: 0 to 1% O2
  • Cell Construction: 316 stainless steel
  • Decimal Places: 1
  • Performance

Accuracy:

  • General Use: ±0.1% O2
  • Stable Environment: ±0.1% O2

  • Zero Drift, Per Week: ±0.2% O2
  • Response Time (T90): <15 seconds
  • Tilt Effect, at 15° from Calibration: ±0.15% O2
  • Pressure Effect: Directly proportional to ambient barometric pressure
  • Flow Variation Effect: ±0.1% O2 for a ±0.5 psig (3.5kPa) change
  • Operating Temperature: -10 to 50°C (14 to 122°F)

Temperature Coefficient:

  • Zero: ±0.2% O2 per 10°C (18°F)
  • Span: ±0.3% O2 per 10°C (18°F)

Sample

  • Sample Gas: Clean, dry, non-flammable and non-toxic gases only
  • Note: Though samples containing >5% CO2 are toxic they can be analyzed if suitable precautions are taken.
  • Flow Control: To maximize measurement stability, unpumped units are supplied with an automatic flow control device (AFCD); over the specified inlet pressure range this controls sample flow rate to approximately 1.5 to 6 liters (0.05 to 0.2 cubic feet) per minute
  • Sample Inlet Connection: 5 mm (0.19″) OD stub with “quickconnect” barb fitting for 6.3 mm (¼”) ID tube or adaptor to 1/8 NPT fitting option
  • Sample Outlet Connection: 5 mm (0.19″) OD stub (sample and bypass)

Inlet Pressure:

  • Without Pump: 7kPa to 70kPa (1 to 10 psig)
  • With Internal Pump (Optional): -7kPa to 3.5kPa (-1 to 0.5 psig)
  • Sample Filter: Replaceable 0.6 µm glass fiber particulate filter
  • Response Time: All at 70kPa (10 psig)
  • Flow Effect: AFCD version, within specified sample gas supply range
  • Dimensions: 150 W x 260 D x 300 mm H (6 x 10.5 x 12″)
  • Weight: 2.6 to 3.9 kg (5.7 to 8.6 lb), depending on configuration

The OMEGA GAB-1700 oxygen analyzer has been specifically designed to meet the demanding needs of field and laboratory analysts, light industrial users and others who require fast, accurate and reliable analysis of common gas mixtures. This compact, portable and easy to use instrument is based upon a non-depleting, component specific measurement technique (magnetodynamic paramagnetic) for long life and minimal running costs, avoiding the problems associated with electrochemical or other less robust methods of analysis.

Specifications

  • Gases Measured Oxygen (O2) Sensors Oxygen
  • Technology: Paramagnetic
  • Variant: Industrial
  • Full Scale Range (FSR): 0 to 100% O2
  • Minimum Output Range: 0 to 1% O2
  • Cell Construction: 316 stainless steel
  • Decimal Places: 1
  • Performance

Accuracy:

  • General Use: ±0.1% O2
  • Stable Environment: ±0.1% O2

  • Zero Drift, Per Week: ±0.2% O2
  • Response Time (T90): <15 seconds
  • Tilt Effect, at 15° from Calibration: ±0.15% O2
  • Pressure Effect: Directly proportional to ambient barometric pressure
  • Flow Variation Effect: ±0.1% O2 for a ±0.5 psig (3.5kPa) change
  • Operating Temperature: -10 to 50°C (14 to 122°F)

Temperature Coefficient:

  • Zero: ±0.2% O2 per 10°C (18°F)
  • Span: ±0.3% O2 per 10°C (18°F)

Sample

  • Sample Gas: Clean, dry, non-flammable and non-toxic gases only
  • Note: Though samples containing >5% CO2 are toxic they can be analyzed if suitable precautions are taken.
  • Flow Control: To maximize measurement stability, unpumped units are supplied with an automatic flow control device (AFCD); over the specified inlet pressure range this controls sample flow rate to approximately 1.5 to 6 liters (0.05 to 0.2 cubic feet) per minute
  • Sample Inlet Connection: 5 mm (0.19″) OD stub with “quickconnect” barb fitting for 6.3 mm (¼”) ID tube or adaptor to 1/8 NPT fitting option
  • Sample Outlet Connection: 5 mm (0.19″) OD stub (sample and bypass)

Inlet Pressure:

  • Without Pump: 7kPa to 70kPa (1 to 10 psig)
  • With Internal Pump (Optional): -7kPa to 3.5kPa (-1 to 0.5 psig)
  • Sample Filter: Replaceable 0.6 µm glass fiber particulate filter
  • Response Time: All at 70kPa (10 psig)
  • Flow Effect: AFCD version, within specified sample gas supply range
  • Dimensions: 150 W x 260 D x 300 mm H (6 x 10.5 x 12″)
  • Weight: 2.6 to 3.9 kg (5.7 to 8.6 lb), depending on configuration

Would you like to know more?

Our team can help you with any product information, quotes, or any general questions you may have about the product.

Product logos in a grid

Your no.1 solution to all of your workwear needs

Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.

Product logos in a grid

Product Selected

Portable Oxygen Analyser

Make an Enquiry

"*" indicates required fields

*
Country
Hidden
This field is for validation purposes and should be left unchanged.

In a rush? Call our team today

|

Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter