Formaldehyde Monitor and Data Logger

AQM-101
Download PDFs:
PDF Icon

The AQM-101 is designed to measure and record Formaldehyde (HCHO) concentration, air temperature and relative humidity with visible and audible alarms. This HCHO monitor is an ideal instrument for indoor air quality (IAQ) monitoring and local exhaust system (LEV) performance verification in areas where Formaldehyde may be present.

FORMALDEHYDE (HCHO) is a gaseous component of the earth’s atmosphere. The concentration of HCHO in natural ambient air is about 0.03 ppm.

The UK Control of Substances Hazardous to Health (COSHH) Regulations 2002 impose a legal requirement for the workplace control of exposure to Formaldehyde, by reference to Table 1 of EH40/2005 Workplace Exposure Limits (WELs).

The short-term exposure limit for Formaldehyde as listed in EH40* is 2 ppm or 2.5 mg/m³ (15 minute reference period). 

SPECIFICATIONS

HCHO –

  • Measurement Range: 0.00 to 5.00 ppm @25°C, ambient pressure
  • Accuracy (0.00 to 5.00 ppm): ±5%, + 0.03 ppm
  • Resolution: 0.01 ppm

Temperature –

  • Range: 0 to 50°C (32 to 122°F)
  • Accuracy: ±0.1°C (2°F) [0 to 50°C (32 to 122°F)]
  • Resolution: 1°C (1°F)

Relative Humidity –

  • Range: 10 to 80% RH
  • Accuracy: ±3% RH [at 25°C, from 10 to 80 RH], ±5% RH below 10%

  • Memory Capacity: 32,000 readings
  • Storage Temperature: -40 to 70°C
  • Interface: USB
  • Response Time: Less than 30 seconds (T90)
  • Dimensions: 110 H x 108 W x 28 mm D 
  • Weight: 165 g

The AQM-101 is designed to measure and record Formaldehyde (HCHO) concentration, air temperature and relative humidity with visible and audible alarms. This HCHO monitor is an ideal instrument for indoor air quality (IAQ) monitoring and local exhaust system (LEV) performance verification in areas where Formaldehyde may be present.

FORMALDEHYDE (HCHO) is a gaseous component of the earth’s atmosphere. The concentration of HCHO in natural ambient air is about 0.03 ppm.

The UK Control of Substances Hazardous to Health (COSHH) Regulations 2002 impose a legal requirement for the workplace control of exposure to Formaldehyde, by reference to Table 1 of EH40/2005 Workplace Exposure Limits (WELs).

The short-term exposure limit for Formaldehyde as listed in EH40* is 2 ppm or 2.5 mg/m³ (15 minute reference period). 

SPECIFICATIONS

HCHO –

  • Measurement Range: 0.00 to 5.00 ppm @25°C, ambient pressure
  • Accuracy (0.00 to 5.00 ppm): ±5%, + 0.03 ppm
  • Resolution: 0.01 ppm

Temperature –

  • Range: 0 to 50°C (32 to 122°F)
  • Accuracy: ±0.1°C (2°F) [0 to 50°C (32 to 122°F)]
  • Resolution: 1°C (1°F)

Relative Humidity –

  • Range: 10 to 80% RH
  • Accuracy: ±3% RH [at 25°C, from 10 to 80 RH], ±5% RH below 10%

  • Memory Capacity: 32,000 readings
  • Storage Temperature: -40 to 70°C
  • Interface: USB
  • Response Time: Less than 30 seconds (T90)
  • Dimensions: 110 H x 108 W x 28 mm D 
  • Weight: 165 g

Would you like to know more?

Our team can help you with any product information, quotes, or any general questions you may have about the product.

Product logos in a grid

Your no.1 solution to all of your workwear needs

Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.

Product logos in a grid

Product Selected

Formaldehyde Monitor and Data Logger

Make an Enquiry

"*" indicates required fields

*
Country
Hidden
This field is for validation purposes and should be left unchanged.

In a rush? Call our team today

|

Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter