This rugged high-performance and low power consumption OMEGA® ZW-ED wireless sensor/transmitter system provides web-based monitoring temperature, humidity, and barometric pressure.

The radio is an IEEE 802.15.4 compliant transmitter operating at 2.4 GHz designed to transmit up to 1000m* (3280”) outdoor and around 100m* (328”) indoor to a ZW-REC coordinator. The ZW-REC connects directly to an Ethernet network to serve active web pages and display the data. You can monitor and record temperature, relative humidity, and barometric pressure over an Ethernet network with no special software—just your web browser.

These wireless devices are designed for demanding industrial applications indoors and harsh outdoor environments. The electronics are protected in a rugged weatherproof polycarbonate NEMA 4 (IP65) rated housing. A variety of compatible probes are available to suit your application.

* Without obstructions or interference

Specifications:

Inputs Type

Digital Probe: Temperature, Barometric Pressure, and Humidity

EXTERNAL SENSOR SPECIFICATIONS 

TEMPERATURE 

Accuracy/Range**: 

  • zTP1 (-P/-LCD/-DC/-CCELL); zTP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 10° to 85°C (±1°F for 50° to 185°F) ±1°C for -40° to 10°C and 85° to 125°C (±1.8°F for -40° to 50°F and 185° to 257°F) 
  • zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) zTHP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 5° to 45°C (±1°F for 41° to 113°F) up to 1.5°C for -40° to 5°C and 45° to 124°C (up to 2.7°F for -40° to 41°F and 113° to 255°F)
  • zBTP (-P/-LCD/-DC/-CCELL) ±0.8°C @ 20°C (±1.5°F @ 68°F) ±2°C for -40° to 85°C (±3.6°F for -40° to 185 °F) 
  • Resolution: 0.1°C 
  • Repeatablilty: ±0.1°C, for zBTHP, zTHP, zTHP2 (-P/-LCD/-DC/-CCELL), 

**Note: extended temperature ranges are for External Probes only 

Industrial Probe: 

  • SS 316 housing, 137mm x Ø16mm (5” x Ø 0.63”) for zBTP (-P/-LCD/-DC/-CCELL); zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) 
  • Short Probe, Quick Disconnect: SS 316 housing, 78mm x Ø16mm (3.1” x Ø 0.63”) for zTHP2 (-P/-LCD/-DC/-CCELL) 
  • Stick Probe: ABS tubing, 152.4 mm x Ø6.35 mm (6” x Ø 0.25”) for zTP1 (-P/-LCD/-DC/-CCELL) 
  • Lug Mounted Probe: Copper tubing, 53.4 mm x Ø 7.92mm (2.1” x Ø 0.312”); mounting hole Ø 4.72mm (Ø 0.186”) forzTP2 (-P/-LCD/-DC/-CCELL) 

Cable Dimensions and Operating Temperature: 

  • 3 m (10’) long x Ø 2.62 mm (0.103”) -80° to 200°C (-112° to 392°F) for zTHP (-P/-LCD/-DC/-CCELL); zTP1 (-P/-LCD/-DC/-CCELL); zTP2 (-P/-LCD/-DC/-CCELL) 
  • 3 m (10’) long x Ø 4.45 mm (0.175”) -55 to 105°C (-67 to 221°F) for zBTP (-P/-LCD/-DC/-CCELL); zBTHP (-P/-LCD/-DC/-CCELL)

RELATIVE HUMIDITY 

  • Accuracy/Range: zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) ±2% for 10 to 90%; ±3% for 5 to 10% and 90 to 95%; ±4% for 0 to 5% and 95 to 100% 
  • Hysteresis: ±1% RH 
  • Non-linearity: ±3% 
  • Repeatability: ±0.1% 
  • Resolution: 0.1% 

BAROMETRIC PRESSURE 

  • Accuracy/Range: zBTP (-P/-LCD/-DC/-CCELL), zBTHP (-P/-LCD/-DC/-CCELL); ±2 mbar for 10 mbar to 1100 mbar (1 KPa to 110 KPa) 
  • Resolution: 0.1 mbar 

THERMOCOUPLE INPUT (Coming Soon) 

  • Temperature Stability: 0.08°C/°C 
  • Temperature Coefficient: ±25 ppm/°C 
  • Thermocouple Cold End Tracking: 0.1°C/°C 
  • Thermocouple Lead Resistance: 100 ohm max. 
  • Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L (DIN J) 
  • Warm-Up to Rated Accuracy: 30 minutes 

ANALOG VOLTAGE & CURRENT INPUT (Coming soon) 

  • Voltage Input: Differential; bipolar; ±100 mV, ±1 V, ±10 V 
  • Input Impedance: 400 K ohm for voltage 
  • Current Input: Differential; bipolar; ±20 mA (5 Ohm load) 
  • Accuracy: ±0.1% Full Range @ 25°C 
  • Reading Rate: Periodic (1 sample/update) or continuous (20 samples/second) 
  • A/D Conversion: Sigma-Delta 
  • Resolution: 16 bits 
  • Temperature Coefficient: ±50 ppm/°C 
  • Common Mode Rejection: 105 dB 
  • Normal Mode Rejection: 98 dB 
  • Warm-Up to Rated Accuracy: 30 minutes

Environmental

Operating Conditions:

  • Base Unit: -20 to 70°C (-4 to 158°F), 90% RH non-condensing
  • CR2032 Battery: -20 to 60°C (-4 to 140°F), 90% RH non-condensing
  • Alkaline Battery: -18 to 55°C (-0.4 to 131°F), 90% RH non-condensing
  • LCD Option: -10 to 60°C (14 to 140°F), 90% RH non-condensing

Packaging

  • Enclosure Material: Polycarbonate
  • Enclosure Protection: NEMA 4 (IP65)
  • Enclosure Dimensions: 135.9 L x 82 W x 39 mm D (5.35 x 3.23 x 1.56″)

General

  • Agency Approval: ECCN 5A992, EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU, FCC ID T40JN5168M5 
  • Software: Compatible with the OMEGA® Dashboard 

Note: Because of transmission frequency regulations, the ZW series products may only be used in the United States, Canada, Europe, China, Japan, Korea, Mexico and Brazil.

This rugged high-performance and low power consumption OMEGA® ZW-ED wireless sensor/transmitter system provides web-based monitoring temperature, humidity, and barometric pressure.

The radio is an IEEE 802.15.4 compliant transmitter operating at 2.4 GHz designed to transmit up to 1000m* (3280”) outdoor and around 100m* (328”) indoor to a ZW-REC coordinator. The ZW-REC connects directly to an Ethernet network to serve active web pages and display the data. You can monitor and record temperature, relative humidity, and barometric pressure over an Ethernet network with no special software—just your web browser.

These wireless devices are designed for demanding industrial applications indoors and harsh outdoor environments. The electronics are protected in a rugged weatherproof polycarbonate NEMA 4 (IP65) rated housing. A variety of compatible probes are available to suit your application.

* Without obstructions or interference

Specifications:

Inputs Type

Digital Probe: Temperature, Barometric Pressure, and Humidity

EXTERNAL SENSOR SPECIFICATIONS 

TEMPERATURE 

Accuracy/Range**: 

  • zTP1 (-P/-LCD/-DC/-CCELL); zTP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 10° to 85°C (±1°F for 50° to 185°F) ±1°C for -40° to 10°C and 85° to 125°C (±1.8°F for -40° to 50°F and 185° to 257°F) 
  • zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) zTHP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 5° to 45°C (±1°F for 41° to 113°F) up to 1.5°C for -40° to 5°C and 45° to 124°C (up to 2.7°F for -40° to 41°F and 113° to 255°F)
  • zBTP (-P/-LCD/-DC/-CCELL) ±0.8°C @ 20°C (±1.5°F @ 68°F) ±2°C for -40° to 85°C (±3.6°F for -40° to 185 °F) 
  • Resolution: 0.1°C 
  • Repeatablilty: ±0.1°C, for zBTHP, zTHP, zTHP2 (-P/-LCD/-DC/-CCELL), 

**Note: extended temperature ranges are for External Probes only 

Industrial Probe: 

  • SS 316 housing, 137mm x Ø16mm (5” x Ø 0.63”) for zBTP (-P/-LCD/-DC/-CCELL); zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) 
  • Short Probe, Quick Disconnect: SS 316 housing, 78mm x Ø16mm (3.1” x Ø 0.63”) for zTHP2 (-P/-LCD/-DC/-CCELL) 
  • Stick Probe: ABS tubing, 152.4 mm x Ø6.35 mm (6” x Ø 0.25”) for zTP1 (-P/-LCD/-DC/-CCELL) 
  • Lug Mounted Probe: Copper tubing, 53.4 mm x Ø 7.92mm (2.1” x Ø 0.312”); mounting hole Ø 4.72mm (Ø 0.186”) forzTP2 (-P/-LCD/-DC/-CCELL) 

Cable Dimensions and Operating Temperature: 

  • 3 m (10’) long x Ø 2.62 mm (0.103”) -80° to 200°C (-112° to 392°F) for zTHP (-P/-LCD/-DC/-CCELL); zTP1 (-P/-LCD/-DC/-CCELL); zTP2 (-P/-LCD/-DC/-CCELL) 
  • 3 m (10’) long x Ø 4.45 mm (0.175”) -55 to 105°C (-67 to 221°F) for zBTP (-P/-LCD/-DC/-CCELL); zBTHP (-P/-LCD/-DC/-CCELL)

RELATIVE HUMIDITY 

  • Accuracy/Range: zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) ±2% for 10 to 90%; ±3% for 5 to 10% and 90 to 95%; ±4% for 0 to 5% and 95 to 100% 
  • Hysteresis: ±1% RH 
  • Non-linearity: ±3% 
  • Repeatability: ±0.1% 
  • Resolution: 0.1% 

BAROMETRIC PRESSURE 

  • Accuracy/Range: zBTP (-P/-LCD/-DC/-CCELL), zBTHP (-P/-LCD/-DC/-CCELL); ±2 mbar for 10 mbar to 1100 mbar (1 KPa to 110 KPa) 
  • Resolution: 0.1 mbar 

THERMOCOUPLE INPUT (Coming Soon) 

  • Temperature Stability: 0.08°C/°C 
  • Temperature Coefficient: ±25 ppm/°C 
  • Thermocouple Cold End Tracking: 0.1°C/°C 
  • Thermocouple Lead Resistance: 100 ohm max. 
  • Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L (DIN J) 
  • Warm-Up to Rated Accuracy: 30 minutes 

ANALOG VOLTAGE & CURRENT INPUT (Coming soon) 

  • Voltage Input: Differential; bipolar; ±100 mV, ±1 V, ±10 V 
  • Input Impedance: 400 K ohm for voltage 
  • Current Input: Differential; bipolar; ±20 mA (5 Ohm load) 
  • Accuracy: ±0.1% Full Range @ 25°C 
  • Reading Rate: Periodic (1 sample/update) or continuous (20 samples/second) 
  • A/D Conversion: Sigma-Delta 
  • Resolution: 16 bits 
  • Temperature Coefficient: ±50 ppm/°C 
  • Common Mode Rejection: 105 dB 
  • Normal Mode Rejection: 98 dB 
  • Warm-Up to Rated Accuracy: 30 minutes

Environmental

Operating Conditions:

  • Base Unit: -20 to 70°C (-4 to 158°F), 90% RH non-condensing
  • CR2032 Battery: -20 to 60°C (-4 to 140°F), 90% RH non-condensing
  • Alkaline Battery: -18 to 55°C (-0.4 to 131°F), 90% RH non-condensing
  • LCD Option: -10 to 60°C (14 to 140°F), 90% RH non-condensing

Packaging

  • Enclosure Material: Polycarbonate
  • Enclosure Protection: NEMA 4 (IP65)
  • Enclosure Dimensions: 135.9 L x 82 W x 39 mm D (5.35 x 3.23 x 1.56″)

General

  • Agency Approval: ECCN 5A992, EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU, FCC ID T40JN5168M5 
  • Software: Compatible with the OMEGA® Dashboard 

Note: Because of transmission frequency regulations, the ZW series products may only be used in the United States, Canada, Europe, China, Japan, Korea, Mexico and Brazil.

Would you like to know more?

Our team can help you with any product information, quotes, or any general questions you may have about the product.

Product logos in a grid

Your no.1 solution to all of your workwear needs

Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.

Product logos in a grid

Product Selected

Wireless Monitoring System – Low Power Transmitters

Make an Enquiry

"*" indicates required fields

*
Country
Hidden
This field is for validation purposes and should be left unchanged.

In a rush? Call our team today

|

Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter