Turbine Meters For Water Totalisation

FTB-4000 Series
Download PDFs:
PDF Icon

OMEGA’s FTB-4000 flowmeters are highly accurate and feature tamper-resistant, non-resettable totalizers. The large faces are easy to read. Optional reed relay scaled pulse outputs allow for remote totalization (1.8 m of cable included). The pulse output option is factory installed and must be requested at the time of order. All FTB flowmeters feature built-in strainers, trickle flow indication and are shipped complete with locking nuts and coupling pieces.

Specifications

  • Accuracy: from 10% of cont. to max. flow : ±1.5% of reading; below 10% of cont. flow: ±2% of reading 
  • Power for Pulse Output: 6-16 Vdc
  • Max. Temp: 90°C 
  • Max. Pressure: 150 psi 
  • Pulse Outputs: Reed Relay: 4100P Series: 1 gal/pulse (for remote totalization only)
  • Max. Reading (gals): 10 million for 1 /2 ” and 3 /4 “; 100 million for 1”, 1 1 /4 “, 1 1 /2 ” 
  • Wetted Parts: Brass body, stainless steel polyimide (fiberglass), polypropylene, EPDM O-Ring 
  • Installation Requirements: 10 pipe diameters upstream, 5 downstream 
  • Mounting: Horizontal or vertical for 1 /2 ” and 3 /4 ” models, Horizontal Mounting Required for 1″, 1 1 /4 “, 1 1 /2 ” models. 

OMEGA’s FTB-4000 flowmeters are highly accurate and feature tamper-resistant, non-resettable totalizers. The large faces are easy to read. Optional reed relay scaled pulse outputs allow for remote totalization (1.8 m of cable included). The pulse output option is factory installed and must be requested at the time of order. All FTB flowmeters feature built-in strainers, trickle flow indication and are shipped complete with locking nuts and coupling pieces.

Specifications

  • Accuracy: from 10% of cont. to max. flow : ±1.5% of reading; below 10% of cont. flow: ±2% of reading 
  • Power for Pulse Output: 6-16 Vdc
  • Max. Temp: 90°C 
  • Max. Pressure: 150 psi 
  • Pulse Outputs: Reed Relay: 4100P Series: 1 gal/pulse (for remote totalization only)
  • Max. Reading (gals): 10 million for 1 /2 ” and 3 /4 “; 100 million for 1”, 1 1 /4 “, 1 1 /2 ” 
  • Wetted Parts: Brass body, stainless steel polyimide (fiberglass), polypropylene, EPDM O-Ring 
  • Installation Requirements: 10 pipe diameters upstream, 5 downstream 
  • Mounting: Horizontal or vertical for 1 /2 ” and 3 /4 ” models, Horizontal Mounting Required for 1″, 1 1 /4 “, 1 1 /2 ” models. 

Would you like to know more?

Our team can help you with any product information, quotes, or any general questions you may have about the product.

Product logos in a grid

Your no.1 solution to all of your workwear needs

Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.

Product logos in a grid

Product Selected

Turbine Meters For Water Totalisation

Make an Enquiry

"*" indicates required fields

*
Country
Hidden
This field is for validation purposes and should be left unchanged.

In a rush? Call our team today

|

Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter