Over the years, Gas Clip Technologies has pioneered and perfected the development of advanced infrared LEL sensor technology for portable gas detection. Low-power LED photometric infrared technology for LEL detection of hydrocarbon gases has reduced detector maintenance, downtime and expenses. It has also made daily charging of portable multi gas detectors a thing of the past.
We offer this technology in each of our multi gas detectors which enables them to run continuously for days, months or even years at a time. This technology also enables these detectors to operate in oxygen deficient environments and to not suffer from LEL sensor poisoning. We also offer reliable single gas detectors for hydrogen sulfide (H2S), carbon monoxide (CO) or oxygen (O2) as well as quick and efficient docking stations for all our detectors.
Gas Clip Technologies offers solutions to typical safety issues with compliance-based detectors that are customisable, durable, and user friendly. 100% of our detectors are quality tested to ensure customer satisfaction and low cost of ownership. All products are assembled in the USA and sold through local distributorships around the world. Our experienced Gas Clip Technologies team is here to help you solve your most difficult gas detection challenges.
Rugged and economical to use
Gas Clip Technologies Single Gas Clip Dock (SGC Dock) is an all in one docking station designed for maximum testing efficiency and portability. Housed in a rugged case with robust USB memory, this station will be able to accurately test and record all monitor data while reducing the testing time and gas usage.
Why test just one when you can test 4!
Traditional docking stations are only designed to test one instrument at a time, resulting in time consuming testing periods as well as unnecessary usage of testing gas. Gas Clip Technologies has significantly improved both testing time and test gas usage with the SGC Dock; users can now test 4 instruments simultaneously saving both time and money.
Detector Configuration/Firmware Updates: In order to keep your fleet of gas detectors compliant with specific settings, we allow for the SGC Dock to program each detector during either bump testing or calibration. The programmable fields are as follows: User ID, Calibration Interval, Bump Interval, Self-Test Interval, Low Alarm, High Alarm, Show Sensor Readings, Hide Bump Due LED and Hide Clock. For example, if your company or facility requires each detector on site to have specific alarm set points and a bump test interval, instead of programming each detector individually, the instruments can be group programmed while simultaneously bump testing (4 detectors at a time per dock) using our GCT Manager software. As firmware updates become available, we can program each SGC Dock to update detectors during bump testing and calibration. Facility safety standard compliance for single gas detectors is now easily achievable.
Event Data and Record Storage: In addition to performing tests, detector configurations and firmware updates, the SGC Dock also stores important information about both the docking station and detectors tested. All tests performed on the docking station can be accessed from either the USB directly or using the GCT Manager software. Each bump test and calibration event is recorded and logged by date, time and serial number. Along with the test records, the individual event logs from each detector are saved. At the time of the test, the detector transmits its’ event log to the memory. By default, the station will save the previous 10 event logs.
SGC Dock Wall Mount : Gas Clip Technologies offers a wall mount solution for our SGC Dock. Instead of being housed in a case, we provide a slim cabinet type case that can be easily mounted on a wall. This option can be selected at the time of order or can be ordered separately to convert your existing SGC Dock to a SGC Dock Wall Mount. This option is a perfect fit for facilities or office environments.
Gas Clip Technologies GCT Manager software provides users the ability to communicate and program the SGC Dock or SGC Dock Wall Mount via IR Link or USB memory stick. In order to communicate with a SGC Dock system via infrared, an IR Link is required.
Following is a full list of programmable features offered when communicating with the SGC Dock or SGC Dock Wall Mount using the GCT Manager Software via the IR Link:
*System Requirements: Available for Windows© based PCs (XP, Vista, Windows 7) ; Users must also install Microsoft Net 4.0 software.
Our team can help you with any product information, quotes, or any general questions you may have about the product.
Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.