The OM-SQ2010 is a versatile general purpose data logger with 4 to 8 analogue input channels to measure current, voltage, resistance and temperature, plus 8 digital channels to automatically trigger or stop logging. An RS-232 port is included, allowing connection to modems and other networking devices. This is a portable data logger which is also suitable for benchtop and fixed installations. The unit is easily programmed via the four integral push buttons and large graphical display or via the included Windows® software. The OM-SQ2010 is able to fulfill many routine data logging needs, including more demanding applications requiring up to ten readings per second on one channel.

Comprehensive Software Configuration:

The OM-SQ-SOFT software (supplied with the OM-SQ2010 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2010. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. 

The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2010 data logger in a familiar windows explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get a statistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels. 

The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data.

Specifications

No. of Analogue Channels: 8 single ended or 4 differential inputs. The OM-SQ2010 data logger has a single analogue to digital converter (A/D) which corresponds to inputs on blocks A and B. Each connection block will accept up to 2 differential inputs or up to 4 single ended inputs (it is not possible to mix single ended and differential inputs on a block).

Analogue Input Connections: Detachable screw terminal blocks

Channel Expansion: No

Universal Input: Yes

Voltage Ranges (Differential and Single Ended): -6 to 25, -0.6 to 2.4, ±0.3V, -0.15 to 0.15, -0.075 to 0.075, -6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2, -0.6 to 0.6

Common Mode: 25 V

Current Ranges, Differential (Requires External 10 Ω Shunt): 4 to 20 mA, ±30 mA

Thermocouple Ranges (Differential and Single Ended):

  • Type J: -200 to 1200°C (-328 to 2192°F)
  • Type K: -200 to 1372°C (-328 to 2502°F)
  • Type T: -200 to 400°C (-328 to 752°F)
  • Type N: -200 to 1300°C (-328 to 2372°F)
  • Type R: -50 to 1768°C (-58 to 3214°F)
  • Type S: -50 to 1768°C (-58 to 3214°F)

Resistance Ranges (All 2 Wire): 0 to 1250 Ω, 0 to 5000 Ω 0 to 20,000 Ω, 0 to 300,000 Ω

Thermistor Ranges:

  • U & UU-Type: -50 to 150°C (-58 to 302°F),
  • Y-Type: -50 to 150°C (-58 to 302°F)
  • S-Type: -30 to 150°C (-22 to 302°F)

User-Defined Thermistor: Enter Steinhart-Hart coefficients or RT pairs

Pt100/1000 (2-wire): -200 to 850°C (-328 to 1562°F)

A/D Resolution: 24 bit

Accuracy: See table on pdf data sheet

Internal Reference Temperature: -50 to 150°C (-58 to 302°F)

Pulse Count Ranges: 0 to 100 Hz (1 input); 0 to 64 kHz (1 input); 0 to 16,000,000 count

Digital State/Event Ranges: 8 state inputs or 1 x 8 bit binary

Digital/Alarm Outputs: 2 open drain FETs, 18V, 0.1A

Digital I/O Connections: DB25F connector

Clock Resolution/Accuracy: 1s/10 ppm Normal Mode – each input sampled at a max rate of 1 rdg per second. Double-Speed (Mains Reject Off) – One input can be sampled at 10 rdgs per second and all others are sampled at a max rate of 1 rdg per second

No of Intervals: 4

Data Scaling: Included in standard OM-SQ software

Data Statistics: Calculated within OM-SQ-SOFT-PLUS software

Calculated Channels: Up to 16

Memory Internal: 16 M (1 to 14 million readings)

Display/Keypad: 128 x 64 dot graphical display, 4 button keypad

Power: 2 C cells internal (included), or external 8 to 28 Vdc via AC adaptor and USB when plugged in

Battery Life: Up to 5 days with continuous usage while sampling all channels once per second

Sensor Power Output: 5 V at 50 mA, external 8 to 28V at 100 mA (when connected)

Networking: Via RS-232 to Ethernet adaptor (Model No. OM-SQ-NET-ADAP)

Modem Support : Via RS-232 modem (GSM modem kit Model No. OM-SQ-GSM-KIT)

PC Setup: Complete data logger set up possible via OM-SQ software;

Compatible with Windows XP SP3/Vista/7 and 8 (32-bit and 64-bit)

Front Panel Setup: Via 4 integral keys. All essential functionality available via key pad e.g. channel configuration, start/stop logging etc. Other advanced functions e.g. calculated channels and channel descriptions are available via connection to a PC running OM-SQ data logger software 

Stored Setups: 6

Operating Temperature: -20 to 65°C

Dimensions: 135 D x 175 W x 55 mm H 

Weight: 0.7 kg 

Enclosure: ABS plastic

The OM-SQ2010 is a versatile general purpose data logger with 4 to 8 analogue input channels to measure current, voltage, resistance and temperature, plus 8 digital channels to automatically trigger or stop logging. An RS-232 port is included, allowing connection to modems and other networking devices. This is a portable data logger which is also suitable for benchtop and fixed installations. The unit is easily programmed via the four integral push buttons and large graphical display or via the included Windows® software. The OM-SQ2010 is able to fulfill many routine data logging needs, including more demanding applications requiring up to ten readings per second on one channel.

Comprehensive Software Configuration:

The OM-SQ-SOFT software (supplied with the OM-SQ2010 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2010. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. 

The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2010 data logger in a familiar windows explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get a statistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels. 

The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data.

Specifications

No. of Analogue Channels: 8 single ended or 4 differential inputs. The OM-SQ2010 data logger has a single analogue to digital converter (A/D) which corresponds to inputs on blocks A and B. Each connection block will accept up to 2 differential inputs or up to 4 single ended inputs (it is not possible to mix single ended and differential inputs on a block).

Analogue Input Connections: Detachable screw terminal blocks

Channel Expansion: No

Universal Input: Yes

Voltage Ranges (Differential and Single Ended): -6 to 25, -0.6 to 2.4, ±0.3V, -0.15 to 0.15, -0.075 to 0.075, -6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2, -0.6 to 0.6

Common Mode: 25 V

Current Ranges, Differential (Requires External 10 Ω Shunt): 4 to 20 mA, ±30 mA

Thermocouple Ranges (Differential and Single Ended):

  • Type J: -200 to 1200°C (-328 to 2192°F)
  • Type K: -200 to 1372°C (-328 to 2502°F)
  • Type T: -200 to 400°C (-328 to 752°F)
  • Type N: -200 to 1300°C (-328 to 2372°F)
  • Type R: -50 to 1768°C (-58 to 3214°F)
  • Type S: -50 to 1768°C (-58 to 3214°F)

Resistance Ranges (All 2 Wire): 0 to 1250 Ω, 0 to 5000 Ω 0 to 20,000 Ω, 0 to 300,000 Ω

Thermistor Ranges:

  • U & UU-Type: -50 to 150°C (-58 to 302°F),
  • Y-Type: -50 to 150°C (-58 to 302°F)
  • S-Type: -30 to 150°C (-22 to 302°F)

User-Defined Thermistor: Enter Steinhart-Hart coefficients or RT pairs

Pt100/1000 (2-wire): -200 to 850°C (-328 to 1562°F)

A/D Resolution: 24 bit

Accuracy: See table on pdf data sheet

Internal Reference Temperature: -50 to 150°C (-58 to 302°F)

Pulse Count Ranges: 0 to 100 Hz (1 input); 0 to 64 kHz (1 input); 0 to 16,000,000 count

Digital State/Event Ranges: 8 state inputs or 1 x 8 bit binary

Digital/Alarm Outputs: 2 open drain FETs, 18V, 0.1A

Digital I/O Connections: DB25F connector

Clock Resolution/Accuracy: 1s/10 ppm Normal Mode – each input sampled at a max rate of 1 rdg per second. Double-Speed (Mains Reject Off) – One input can be sampled at 10 rdgs per second and all others are sampled at a max rate of 1 rdg per second

No of Intervals: 4

Data Scaling: Included in standard OM-SQ software

Data Statistics: Calculated within OM-SQ-SOFT-PLUS software

Calculated Channels: Up to 16

Memory Internal: 16 M (1 to 14 million readings)

Display/Keypad: 128 x 64 dot graphical display, 4 button keypad

Power: 2 C cells internal (included), or external 8 to 28 Vdc via AC adaptor and USB when plugged in

Battery Life: Up to 5 days with continuous usage while sampling all channels once per second

Sensor Power Output: 5 V at 50 mA, external 8 to 28V at 100 mA (when connected)

Networking: Via RS-232 to Ethernet adaptor (Model No. OM-SQ-NET-ADAP)

Modem Support : Via RS-232 modem (GSM modem kit Model No. OM-SQ-GSM-KIT)

PC Setup: Complete data logger set up possible via OM-SQ software;

Compatible with Windows XP SP3/Vista/7 and 8 (32-bit and 64-bit)

Front Panel Setup: Via 4 integral keys. All essential functionality available via key pad e.g. channel configuration, start/stop logging etc. Other advanced functions e.g. calculated channels and channel descriptions are available via connection to a PC running OM-SQ data logger software 

Stored Setups: 6

Operating Temperature: -20 to 65°C

Dimensions: 135 D x 175 W x 55 mm H 

Weight: 0.7 kg 

Enclosure: ABS plastic

Would you like to know more?

Our team can help you with any product information, quotes, or any general questions you may have about the product.

Product logos in a grid

Your no.1 solution to all of your workwear needs

Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.

Product logos in a grid

Product Selected

Portable 4/8 Channel Data Logger. Universal Inputs. Built-In Display

Make an Enquiry

"*" indicates required fields

*
Country
Hidden
This field is for validation purposes and should be left unchanged.

In a rush? Call our team today

|

Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter