Four Channel Thermocouple Data Logger, Part of the NOMAD® Family

OM-CP-QUADTEMP-A and OM-CP-QUADTEMP2000
Download PDFs:
PDF Icon

The OM-CP-QUADTEMP-A is a 4 Channel Thermocouple Data Logger, battery powered, standalone. The OM-CP-QUADTEMP2000 is the same 4-channel thermocouple data logger but with an LCD display. The OM-CP-QUADTEMP2000 features on display minimum, maximum and average statistics, as well as a user configurable graphics display that allows for any combination of channels to be displayed. These all-in-one compact, portable, easy to use devices will measure and record up to 500,000 readings per channel (channels can be disabled to increase memory).

The OM-CP-QUADTEMP-A and OM-CP-QUADTEMP2000 are a major leap forward in both size and performance. The real time clock ensures that all data is time and date stamped. The storage medium is nonvolatile solid state memory, providing maximum data security even if the battery becomes discharged. The data logger’s small size allows it to fit almost anywhere. 

Data retrieval is simple. Plug it into an available COM port and the easy to use Windows® software does the rest. The software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can also be exported to a text or Microsoft Excel file. 

SPECIFICATIONS

INTERNAL CHANNEL TEMPERATURE SENSOR

Calibrated Accuracy: +0.5°C (0°C to +50°C)

Temperature Resolution: 0.05°C

Temperature Range: -20 to 60°C (-4 to 140°F)

EXTERNAL THERMOCOUPLE CHANNELS

Accuracy:* (Uniform 20°C Internal Temperature):

  • J, K, T, E, N: ±0.5°C
  • R, S, B: ±2.0°C

Temperature Resolution:

  • J, K, T, E, N: 0.1°C
  • R, S, B: 0.5°C

Thermocouple Connection: Female subminiature connectors

Cold Junction Compensation: Automatic, based on internal channel

Maximum Thermocouple Resistance: 1000Ω 100Ω recommended

Thermocouple Types and Ranges:

  • Type J: -210°C to 760°C (-346 to 1400°F)
  • Type K: -270°C to 1370°C (-436 to 2498°F)
  • Type T: -270°C to 400°C (-436 to 752°F)
  • Type E: -270°C to 980°C (-436 to 1796°F)
  • Type R: -50°C to 1760°C (-58 to 3200°F)
  • Type S:- 50°C to 1760°C (-58 to 3200°F)
  • Type B: +50°C to 1820°C (140 to 3308°F)
  • Type N: -270°C to 1300°C (-436 to 2372°F)

GENERAL SPECIFICATIONS

Temperature Calibration: Digital calibration is available

through software

Recording Interval: 4/sec to 1/day selectable in software

Start Time: Start time and date are programmable through software

Real Time Recording: Device may be used with PC to monitor and record data in real time

Memory: 500,000 readings per channel (individual channels can be disabled to increase memory)

Power: 9V lithium battery (included) or external power via included ac adaptor

Battery Life:

  • OM-CP-QUADTEMP-A: 18 months typical;
  • OM-CP-QUADTEMP2000: 18 months typical with display off, 3 months typical with continuous display use

Time Accuracy: +1 minute/month when RS-232C port is not in use

Data Format: Date and time stamped, °C, °F, °K, °R

Weight: 370 g (13 oz)

Computer Interface: PC serial, USB or RS-232C COM, 115,200 baud

Software: WIN98/NT/2000/XP/VISTA (32-bit)/WIN 7 (32-bit) (VISTA and WIN 7 32-bit version only; VISTA and WIN 7 64-bit is not supported)

Operating Environment: -20 to 60°C (-4 to 140°F) 5 to 95% RH non-condensing

Dimensions:

  • OM-CP-QUADTEMP-A: 68 H x 183 W x 26 mm D (2.7 x 7.24 x 1.02″)
  • OM-CP-QUADTEMP2000: 68 H x 183 W x 29 mm D (2.7 x 7.24 x 1.14″)

Weight:

  • OM-CP-QUADTEMP-A: 430 g (15.2 oz)
  • OM-CP-QUADTEMP2000: 420 g (14.8 oz)

Material: Black anodized aluminum

The OM-CP-QUADTEMP-A is a 4 Channel Thermocouple Data Logger, battery powered, standalone. The OM-CP-QUADTEMP2000 is the same 4-channel thermocouple data logger but with an LCD display. The OM-CP-QUADTEMP2000 features on display minimum, maximum and average statistics, as well as a user configurable graphics display that allows for any combination of channels to be displayed. These all-in-one compact, portable, easy to use devices will measure and record up to 500,000 readings per channel (channels can be disabled to increase memory).

The OM-CP-QUADTEMP-A and OM-CP-QUADTEMP2000 are a major leap forward in both size and performance. The real time clock ensures that all data is time and date stamped. The storage medium is nonvolatile solid state memory, providing maximum data security even if the battery becomes discharged. The data logger’s small size allows it to fit almost anywhere. 

Data retrieval is simple. Plug it into an available COM port and the easy to use Windows® software does the rest. The software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can also be exported to a text or Microsoft Excel file. 

SPECIFICATIONS

INTERNAL CHANNEL TEMPERATURE SENSOR

Calibrated Accuracy: +0.5°C (0°C to +50°C)

Temperature Resolution: 0.05°C

Temperature Range: -20 to 60°C (-4 to 140°F)

EXTERNAL THERMOCOUPLE CHANNELS

Accuracy:* (Uniform 20°C Internal Temperature):

  • J, K, T, E, N: ±0.5°C
  • R, S, B: ±2.0°C

Temperature Resolution:

  • J, K, T, E, N: 0.1°C
  • R, S, B: 0.5°C

Thermocouple Connection: Female subminiature connectors

Cold Junction Compensation: Automatic, based on internal channel

Maximum Thermocouple Resistance: 1000Ω 100Ω recommended

Thermocouple Types and Ranges:

  • Type J: -210°C to 760°C (-346 to 1400°F)
  • Type K: -270°C to 1370°C (-436 to 2498°F)
  • Type T: -270°C to 400°C (-436 to 752°F)
  • Type E: -270°C to 980°C (-436 to 1796°F)
  • Type R: -50°C to 1760°C (-58 to 3200°F)
  • Type S:- 50°C to 1760°C (-58 to 3200°F)
  • Type B: +50°C to 1820°C (140 to 3308°F)
  • Type N: -270°C to 1300°C (-436 to 2372°F)

GENERAL SPECIFICATIONS

Temperature Calibration: Digital calibration is available

through software

Recording Interval: 4/sec to 1/day selectable in software

Start Time: Start time and date are programmable through software

Real Time Recording: Device may be used with PC to monitor and record data in real time

Memory: 500,000 readings per channel (individual channels can be disabled to increase memory)

Power: 9V lithium battery (included) or external power via included ac adaptor

Battery Life:

  • OM-CP-QUADTEMP-A: 18 months typical;
  • OM-CP-QUADTEMP2000: 18 months typical with display off, 3 months typical with continuous display use

Time Accuracy: +1 minute/month when RS-232C port is not in use

Data Format: Date and time stamped, °C, °F, °K, °R

Weight: 370 g (13 oz)

Computer Interface: PC serial, USB or RS-232C COM, 115,200 baud

Software: WIN98/NT/2000/XP/VISTA (32-bit)/WIN 7 (32-bit) (VISTA and WIN 7 32-bit version only; VISTA and WIN 7 64-bit is not supported)

Operating Environment: -20 to 60°C (-4 to 140°F) 5 to 95% RH non-condensing

Dimensions:

  • OM-CP-QUADTEMP-A: 68 H x 183 W x 26 mm D (2.7 x 7.24 x 1.02″)
  • OM-CP-QUADTEMP2000: 68 H x 183 W x 29 mm D (2.7 x 7.24 x 1.14″)

Weight:

  • OM-CP-QUADTEMP-A: 430 g (15.2 oz)
  • OM-CP-QUADTEMP2000: 420 g (14.8 oz)

Material: Black anodized aluminum

Would you like to know more?

Our team can help you with any product information, quotes, or any general questions you may have about the product.

Product logos in a grid

Your no.1 solution to all of your workwear needs

Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.

Product logos in a grid

Product Selected

Four Channel Thermocouple Data Logger, Part of the NOMAD® Family

Make an Enquiry

"*" indicates required fields

*
Country
This field is hidden when viewing the form
This field is for validation purposes and should be left unchanged.

In a rush? Call our team today

|

Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter