Data Logger with Universal Inputs

OM-SQ2040
Download PDFs:
PDF Icon

The universal data logger of the OM-SQ2040 Series combines a higher channel count with the same high performance, comprehensive features and universal inputs as the OM-SQ2020 in a neat compact and portable instrument. Using multiple 24-bit analogue to digital convertors, twin processors and removable memory options provide great flexibility to handle a wide range of complex and demanding multichannel applications.

The OM-SQ2040 series are the ideal data loggers for industrial, scientific research and quality assurance applications. The OM-SQ2040 provides standalone data acquisition, advanced networked solutions and data analysis straight out-of-the-box.

Input Connections:

The OM-SQ2040-2F16 data logger has two analogue to digital converters (A/D’s) which increases logging flexibility over the OM-2020-1F8 model. The first corresponds to inputs on blocks A, B, C and D and the second corresponds to inputs on blocks G, H, J and K. Each connection block will accept up to 2 differential inputs or up to 4 single-ended inputs (it is not possible to mix single ended and differential inputs on a block). The OM-SQ2040-4F16 data logger has four analogue to digital converters (A/D’s) which increases logging flexibility over the other OM-SQ2020 and OM-SQ2040 models. The first corresponds to inputs on blocks A and B, the second corresponds to inputs on blocks C and D, the third corresponds to inputs on blocks G and H and the fourth corresponds to inputs on blocks J and K. Each connection block will accept up to 2 differential inputs or up to 4 single— ended inputs (it is not possible to mix single-ended and differential inputs on a block).

Concurrent Sampling:

The OM-SQ2040 series uses multiple analogue to digital converters that enables true concurrent sampling and logging. This allows the user to configure up to 4 channels to log at a rate of 100 Hz while retaining different sample speeds on other channels. This makes the OM-SQ2040 ideal for measuring dynamic parameters that change at different rates such as temperature and pressure. 

Communications:

Ethernet, Wi-Fi (on -WIFI models) USB and RS232 serial ports are built-in. This allows quick connection to either a PC based TCP/IP network, a wireless to PC connection or to a modem for remote data downloading. This flexibility enables global data access and retrieval as well as complete system integration of the OM-SQ2040 series into complex and critical applications. 

Multiple Configurations Stored in the Logger:

Up to six logger configurations (channel type, names, logging speeds, triggers, etc.), together with the current configuration, can be held in the logger’s internal memory. Additional configuration settings can also be loaded from the external MMC/SD memory card. This allows the operator to quickly and easily switch between logger configurations without the need for a PC. 

Comprehensive Software Configuration

The OM-SQ-SOFT software (supplied with the OM-SQ2040 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2040. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2040 data logger in a familiar Explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get astatistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels. 

The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data. 

Specifications

ANALOGUE INPUTS

Accuracy: See table on PDF

Common Mode Rejection: 100 dB

Input Impedance: >1MΩ

Linearity: 0.015%

Series Mode Line Rejection: 50/60 Hz 100 dB

Analogue Input Connections: Detachable screw terminal blocks 

ANALOGUE – DIGITAL CONVERSION

Type: Sigma-Delta

Resolution: 24-bit

Sampling Rate: Up to 10, 20* or 100* readings per second per ADC. * With mains rejection off 

MEMORY

Internal: Up to 128Mb (up to 14 million readings)

External: Up to 1Gb removable MMC/SD (for transferring internal memory & storing setups only)

ALARM OUTPUTS

4 x open drain FET (18 V 0.1 A)

Digital I/O Connections: DB25F connector 

CALCULATED CHANNELS

Up to 16 virtual channels derived from physical input channels 

RESOLUTION

Up to 6 significant digits 

PROGRAMMING/LOGGER SETUP

OM-SQ-SOFT or OM-SQ-SOFT-PLUS software; software compatible with WIN 2000/XP/VISTA/7/8 

COMMUNICATION

Standard: RS-232 (automatic baud rate selection to 115200 baud) Ethernet 10/100 base TCP/IP USB 1.1 and 2.0 compatible; Wi-Fi (on -WIFI models) External Options: GSM, WIFI and PSTN Modems 

POWER SUPPLY

Internal: 6 “AA” alkaline batteries (included)

External: 10 to 18 Vdc reverse polarity and over-voltage protected 

POWER CONSUMPTION @ 9V

Sleep Mode: 600 µA Logging: 40 to 130 mA 

DISPLAY AND KEYPAD

128×64 dot graphical display; 4 button keypad 

OPERATING ENVIRONMENT

Temperature: -30 to 65°C 

Humidity: 90% at 40°C non-condensing 

GENERAL

Power Output for External Device:

Regulated 5 Vdc at 50 mA or logger supply voltage at 100 mA

Time and Date: Built-in clock in 3 formats

Scaling Data: Displays readings in preferred engineering units

Dimensions: 175 H x 235 W x 95 mm D 

Weight: Approx. 1.2 kg 

Enclosure Material: ABS

Memory Modes (Internal Only): Stop when full or overwrite

The universal data logger of the OM-SQ2040 Series combines a higher channel count with the same high performance, comprehensive features and universal inputs as the OM-SQ2020 in a neat compact and portable instrument. Using multiple 24-bit analogue to digital convertors, twin processors and removable memory options provide great flexibility to handle a wide range of complex and demanding multichannel applications.

The OM-SQ2040 series are the ideal data loggers for industrial, scientific research and quality assurance applications. The OM-SQ2040 provides standalone data acquisition, advanced networked solutions and data analysis straight out-of-the-box.

Input Connections:

The OM-SQ2040-2F16 data logger has two analogue to digital converters (A/D’s) which increases logging flexibility over the OM-2020-1F8 model. The first corresponds to inputs on blocks A, B, C and D and the second corresponds to inputs on blocks G, H, J and K. Each connection block will accept up to 2 differential inputs or up to 4 single-ended inputs (it is not possible to mix single ended and differential inputs on a block). The OM-SQ2040-4F16 data logger has four analogue to digital converters (A/D’s) which increases logging flexibility over the other OM-SQ2020 and OM-SQ2040 models. The first corresponds to inputs on blocks A and B, the second corresponds to inputs on blocks C and D, the third corresponds to inputs on blocks G and H and the fourth corresponds to inputs on blocks J and K. Each connection block will accept up to 2 differential inputs or up to 4 single— ended inputs (it is not possible to mix single-ended and differential inputs on a block).

Concurrent Sampling:

The OM-SQ2040 series uses multiple analogue to digital converters that enables true concurrent sampling and logging. This allows the user to configure up to 4 channels to log at a rate of 100 Hz while retaining different sample speeds on other channels. This makes the OM-SQ2040 ideal for measuring dynamic parameters that change at different rates such as temperature and pressure. 

Communications:

Ethernet, Wi-Fi (on -WIFI models) USB and RS232 serial ports are built-in. This allows quick connection to either a PC based TCP/IP network, a wireless to PC connection or to a modem for remote data downloading. This flexibility enables global data access and retrieval as well as complete system integration of the OM-SQ2040 series into complex and critical applications. 

Multiple Configurations Stored in the Logger:

Up to six logger configurations (channel type, names, logging speeds, triggers, etc.), together with the current configuration, can be held in the logger’s internal memory. Additional configuration settings can also be loaded from the external MMC/SD memory card. This allows the operator to quickly and easily switch between logger configurations without the need for a PC. 

Comprehensive Software Configuration

The OM-SQ-SOFT software (supplied with the OM-SQ2040 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2040. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2040 data logger in a familiar Explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get astatistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels. 

The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data. 

Specifications

ANALOGUE INPUTS

Accuracy: See table on PDF

Common Mode Rejection: 100 dB

Input Impedance: >1MΩ

Linearity: 0.015%

Series Mode Line Rejection: 50/60 Hz 100 dB

Analogue Input Connections: Detachable screw terminal blocks 

ANALOGUE – DIGITAL CONVERSION

Type: Sigma-Delta

Resolution: 24-bit

Sampling Rate: Up to 10, 20* or 100* readings per second per ADC. * With mains rejection off 

MEMORY

Internal: Up to 128Mb (up to 14 million readings)

External: Up to 1Gb removable MMC/SD (for transferring internal memory & storing setups only)

ALARM OUTPUTS

4 x open drain FET (18 V 0.1 A)

Digital I/O Connections: DB25F connector 

CALCULATED CHANNELS

Up to 16 virtual channels derived from physical input channels 

RESOLUTION

Up to 6 significant digits 

PROGRAMMING/LOGGER SETUP

OM-SQ-SOFT or OM-SQ-SOFT-PLUS software; software compatible with WIN 2000/XP/VISTA/7/8 

COMMUNICATION

Standard: RS-232 (automatic baud rate selection to 115200 baud) Ethernet 10/100 base TCP/IP USB 1.1 and 2.0 compatible; Wi-Fi (on -WIFI models) External Options: GSM, WIFI and PSTN Modems 

POWER SUPPLY

Internal: 6 “AA” alkaline batteries (included)

External: 10 to 18 Vdc reverse polarity and over-voltage protected 

POWER CONSUMPTION @ 9V

Sleep Mode: 600 µA Logging: 40 to 130 mA 

DISPLAY AND KEYPAD

128×64 dot graphical display; 4 button keypad 

OPERATING ENVIRONMENT

Temperature: -30 to 65°C 

Humidity: 90% at 40°C non-condensing 

GENERAL

Power Output for External Device:

Regulated 5 Vdc at 50 mA or logger supply voltage at 100 mA

Time and Date: Built-in clock in 3 formats

Scaling Data: Displays readings in preferred engineering units

Dimensions: 175 H x 235 W x 95 mm D 

Weight: Approx. 1.2 kg 

Enclosure Material: ABS

Memory Modes (Internal Only): Stop when full or overwrite

Would you like to know more?

Our team can help you with any product information, quotes, or any general questions you may have about the product.

Product logos in a grid

Your no.1 solution to all of your workwear needs

Putting the ‘direct’ in directory since 2009. With our global catalogue of quality safety and environmental monitoring products all under one roof, we put an end to lengthy, saturated searches. At OSE, just find and enquire and we will put you in touch with the right person to make your product purchase.

Product logos in a grid

Product Selected

Data Logger with Universal Inputs

Make an Enquiry

"*" indicates required fields

*
Country
Hidden
This field is for validation purposes and should be left unchanged.

In a rush? Call our team today

|

Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter