Universal RTD Calibrator

The CL515-PLUS works with the RTDs you use including Platinum 100 (alpha = 3850, 3902, 3926) & 1000 (alpha = 3850, 3750) Ω, Copper 10 & 50 Ω, Nickel 100 and 120 Ω. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer “DIAL” plus store any three temperatures for instant recall with the check switch.

Calibrate quickly with automatic output stepping, choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds.

Carry it without worry, it comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in dark areas with the backlit display.

Specifications (Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH for 1 year from calibration)

  • Accuracy: ±(0.015% of Reading + 0.05 Ω)
  • Temperature Drift: ± 0.01% of span outside of 23°C ±10°C (73°C ±18°F) Operating Temperature
  • Range: -25 to 60°C (-10 to 140°F)
  • Relative Humidity Range: 10% ≤RH ≤90% (0 to 35°C), non-condensing, 10% ≤RH ≤70% (35 to 60°C), non-condensing
  • Dimensions: 143 L x 76 W x 41 mmH (5.63 x 3.00 x 1.60″)
  • Weight: 0.34 kg (12.1 oz) including boot and batteries
  • Power: 4 “AA” Alkaline 1.5V (LR6) (included)
  • Battery Life: 50 Hours low Battery low battery indication with nominal 1 hour of operation left. Protection against misconnection over-voltage protection to 60 Vdc (rated for 30 seconds)
  • Display: High contrast graphic liquid crystal display. LED backlighting for use in low lit areas.

Indicate

  • Excitation: Current 0.5 mA nominal
  • Normal Mode Rejection: 50/60 Hz, 50 dB
  • Common Mode Rejection: 50/60 Hz, 120 dB

Source

  • Accuracy: From 1 to 10.2 mA external excitation Current ± (0.015% of Reading + 0.05 Ω)
  • Below: 1 mA of external excitation
  • Current: ± (0.015% of reading + 0.025 mV/mA excitation current + 0.05 Ω)
  • Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω
  • Allowable Excitation Current Range <410 Ωs: 10.2 mA max; steady or pulsed/intermittent
  • Allowable Excitation Current Range 410 to 4001 Ωs: 1 mA max; steady or pulsed/intermittent
  • Pulsed Excitation Current compatibility: DC to 0.01 second pulse width 

Printing Handheld Thermometer

OMEGA’s compact and affordable HH1304P is ideal for applications requiring display and printing of temperature measurements. Dual input features min/max, hi/lo audible alarms (with externally powered alarm driver signals) and differential measurements. This 2-channel unit accepts Type J, K, T or E thermocouple inputs, has a high accuracy and 0.1° resolution. A built-in thermal printer makes hard copies of the temperature measurements, which can be taken at selected intervals. Parameters printed are time, date, temperature, and channel number. Battery powered or optional AC adaptor.

Specifications

  • Environment Conditions: Altitude up to 2000 m (6562′) indoor use only
  • Relatively Humidity: 90% max
  • Operation Temperature: 0 to 50°C (32 to 122°F)
  • Display:4½ digit LCD
  • Sampling Rate: 1 reading per second
  • Power Requirement: Six 1.5V “AAA” alkaline batteries (included) or optional 9 AC adaptor, (9 Vdc, 500 mA minimum)
  • Battery Life (Typical): Approx 30 hrs (interval printing = 60 minutes, excluding beeper) 70 hours (without printing and beeper)
  • Input Protection: 60 Vdc/24Vrtns 
  • Operating Temperature and Humidity: 0 to 50°C (32 to 122°F) below 90% RH
  • Storage Temperature and Humidity: -10 to 60°C (14 to 140°F) below 70% RH
  • Dimensions: 193 L x 74 W x 37 mm H (7.60 x 2.91 x 1.46″)
  • Weight: Approx 365 g (13 oz) with batteries and thermo-paper
  • Printer: Thermo-printing type with 16 characters per line using 38 mm width plain thermal paper
  • Resolution: 0.1°C/0.1°F

Accuracy at 23°C, Below 80% RH:

  • Type K: ±(0.01% rdg + 0.5°C) 0~982°C; ±(0.05% rdg + 0.5°C) 982~1333°C; ±(0.01% rdg + 0.9°F) 32~1800°F; ±(0.05% rdg + 0.9°F) 1800~2431°F
  • Type J: ±(0.01% rdg + 0.5°C) 0~760°C; ±(0.01% rdg + 0.9°F) 32~1400°F
  • Type E: ±(0.01% rdg + 0.5°C) 0~703°C; ±(0.01% rdg + 0.9°F) 32~1297°F
  • Type T: ±(0.01% rdg + 0.5°C) 0~400°C; ±(0.01% rdg + 0.9°F) 32~752°F
  • Type K/J/E/T: ±(0.5% rdg + 0.7°C) -200~0°C; ±(0.5% rdg + 1.4°F) -328~32°F
  • Type K/J/E/T: ±(0.5% rdg + 1.0°C)-200~0°C/ -328~32°C

Measurement Range:

  • Type K: -200~1333°C (-328~2431°F)
  • Type J: -200~760°C (-328~1400°F)
  • Type E: -200~703°C (-328~1297°F)
  • Type T: -200~400°C (-328~752°F)

Four-Channel Data Logger with USB and RS232

The HH309A is a small 4-input thermometer plus a powerful data logger. The unit can store up to 16,000 records per channel at programmed intervals. The REC button is used to start and stop recording. You can store as many data sets as you want until memory is full. The unit comes with Windows-based software (Windows 98, NT, XP, ME, Windows 7) for the display and saving of data.

SPECIFICATIONS 

  • Range: -200 to 1370°C (-328 to 2498°F) 
  • Typical Accuracy: ±0.2% rdg +1°C 
  • Resolution: 0.1° between -200 and 200°C/F, else 1°C/F 
  • Sample Rate: 3 seconds 
  • Operating Conditions: 0 to 50°C (32 to 122°F), 0% to 80% RH (0 to 35°C, 32 to 95°F), 0% to 60% RH (35 to 50°C, 95 to 122°F) 
  • Storage Temperature: -20 to 60°C (-4 to 140°F) 
  • Battery: 9 V (included) 
  • Dimensions: 184 H x 64 W x 30 mm D(7.25 x 2.5 x 1.2″) 
  • Weight: Approx 250 g (8.8 oz)

Handheld Digital Thermocouple Thermometers

Omega Engineering’s handheld digital thermocouple thermometers are water/splash resistant and have a battery life of up to 200 hours. Comes complete with protective rubber boot with tilt stand, 9V alkaline battery and operator’s manual. Temperature models include 1 or 2 beaded wire thermocouples (1 per channel).

Specifications

(Common)

  • Input Type: J or K
  • Power: One 9V battery (included)
  • Battery Life: 200 Hours
  • Dimensions: 192 H x 91 W x 53 mm D (7.6 x 3.6 x 2.2″)
  • Weight: Approx 255 g (9 oz)

(HH501AJK)

  • Display Type: Backlit LCD
  • Number of Digits: 1999
  • Input Channel: 1
  • Temperature Range: -50 to 1370°C (-58 to 1950°F)
  • Resolution: 0.1°/1°
  • Display: 1
  • W/Bead Wire
  • Type K Thermocouple: 1
  • Basic Accuracy, (% Rdg): 0.1% +1°C

(HH501BJK)

  • Display Type: Backlit LCD
  • Number of Digits: 1999
  • Input Channel: 2
  • Temperature Range: -50 to 1370°C (-58 to 1950°F)
  • Resolution: 0.1°/1°
  • Display: 1
  • W/Bead Wire Type K Thermocouple: 2
  • Basic Accuracy: 0.1% +1°C

(HH502)

  • Display Type: LCD
  • Number of Digits: 25,000
  • Input Channel: 2
  • Temperature Range: -200 to 1370°C (-328 to 2498°F)
  • Resolution: 0.1°
  • Display: 3
  • W/Bead Wire Type K Thermocouple: 2
  • Basic Accuracy: 0.05% +0.3°C

(HH503)

  • Display Type: LCD
  • Number of Digits: 25,000
  • Input Channel: 1
  • Temperature Range: -200 to 1370°C (-328 to 2498°F)
  • Resolution: 0.1°
  • Display: 3
  • W/Bead Wire Type K Thermocouple: 1
  • Basic Accuracy: 0.05% +0.3°C

Handheld Digital Thermometers Type R and S Thermocouple, Single and Dual Input

Digital thermometers capable of measuring temperatures up to 1999°F

Specifications:

HH501BR:

  • 1999 Counts
  • Backlit LCD Display
  • Models for Type R or S
  • Thermocouple Input
  • Reading HOLD, Max function
  • Dual input with Differential Function T1-T2

HH501AS:

  • 1999 counts
  • Backlit LCD Display
  • Models for Type Thermocouple
  • Reading HOLD
  • MAX function
  • ITS-90 Accuracy
  • Single Input

4-Channel Type-K Thermometer with Backlit Display

The OMEGA® HH501DK is a rugged, easy to use thermometer with 4 standard miniature connector inputs. It accepts K type thermocouple probes and covers ranges from -50 to 1300°C (-58 to 1999°F). It also provides differential temperature measurement readings of T1-T2, T1-T3, T1-T4, as well as individual readings of the 4 inputs.

Specifications

  • Temperature Range: -50 to 1300°C (-58 to 1999°F)
  • Input: Type K thermocouple
  • Accuracy: ±(0.3% rdg + 1°C) -50 to 1000°C. ±(0.5% rdg + 1°C) 1000 to 1300°C. ±(0.3% rdg + 2°F) -58 to 1999°F
  • Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999
  • Polarity: Automatic, positive implied, negative polarity indication.
  • Overrange: (OL) or (-OL) is displayed
  • Zero: Automatic
  • Low Battery Indication: visual indicator is displayed when battery voltage drops below operating level.
  • Measurement Rate: 2.5 times/sec
  • Operating Environment: 0 to 50°C @ <70% RH
  • Storage Temperature: -20 to 60°C, 0 to 80% RH with battery removed from meter
  • Accuracy: Stated accuracy @ 23°C ±5°C <75% relative humidity. (accuracy specification does not include type K thermocouple probe accuracy)
  • Dimensions: 195 x 92 x 53 mm (7.7 x 3.6 x 2.1″)
  • Weight: Approx. 250 g (9 oz) including battery

Economical Digital Thermometers

Omega’s HH91 and HH92 digital thermometers are ideal for measuring temperature in an industrial, commercial or laboratory environment.

Specifications

  • Measurement Accuracy (Excluding Thermocouple Error) From 18 to 28°C: ±(0.5% of reading + 0.5°C)
  • Measurement Resolution: 0.1° (°F or °C) below 1000°; 1° (°F or °C) above 1000°
  • Measurement Range of Included Thermocouple: -40 to 300°C
  • Auto Power Off Trigger: Adjustable from 5 minutes to 1 hour; can be disabled
  • Operating Temperature: 0 to 50°C @<80% RH
  • Dimensions: 191 x 89 x 41 mm 
  • Weight: 400 g 
  • Power Source: One “9V” battery (included)

Thermocouple Measurement Ranges:

  • Type K: -200 to 1372°C (-328 to 2501°F)
  • Type J: -210 to 1200°C (-346 to 2192°F)
  • Type T: -250 to 400°C (-418 to 752°F)
  • Type E: -150 to 1000°C (-238 to 1832°F)

Handheld Volatile Organic Compound (VOC) Meter

The HHAQ-107 is ideal for making general measurements of mixed gas volatile organic compound (VOC) levels as part of an indoor air quality (IAQ) maintenance program. Much less expensive than photo-ionization meters designed to make precise measurements of VOC levels from a single gas. Small and light weight with a tripod mount fitting, the HHAQ-107 is a versatile tool for HVAC and IAQ technicians. The meters storage capacity can be entirely devoted to VOC readings or split 3 ways for VOC, ambient temperature and relative humidity. The HHAQ-107 incudes powerful data logging software for downloading readings to a PC and printing in table or graph form.

Specifications

  • VOC Measurement Range/Resolution: 0 to 50/0.01 ppm
  • VOC Warmup Time: 10 minutes first use, 2 minutes thereafter
  • VOC Sensor Type/Longevity: Metal-oxide semiconductor/5 years (typical)
  • Temperature Measurement Range: -10 to 50°C (14 to 122°F)
  • Temperature Measurement Accuracy/Resolution: ±0.6°C (1.2°F)/0.1°
  • RH Measurement Range: 10 to 90% RH
  • RH Measurement Accuracy/Resolution: ±5% of reading at 25°C; ±7% of reading elsewhere in range/0.1% RH
  • Dew Point Measurement Range: -73 to 47°C (-99.2 to 118°F)
  • Wet Bulb Measurement Range: -11 to 48.2°C (12.2 to 118.8°F)
  • Data Logging Capacity: 32,004 points
  • Display Type/Size: Dual readout LCD/51 mm diagonal
  • Auto Power-Off Trigger: 15 minutes of front-panel inactivity (can be disabled)
  • Operating Temperature: 0 to 50°C at 0 to 95% RH, non-condensing
  • Dimensions: 210 L x 60 W x 25 mm D
  • Weight: 204 g, including batteries
  • Power Source: (6) “AAA” batteries (included) or optional ac adaptor

EMF Tester with Data Logging

The HHG1392 Gauss meter offers a quick and reliable instrument to measure electromagnetic fields (EMF) in the 200 to 2000 milli Gauss or 20 to 200 micro Tesla range. The HHG1392 can measure and store measurements for downloading into a PC via RS232 with included software or operate real time for live viewing. This meter is used to measure electromagnetic fields (EMF) in the extremely low frequency (ELF) band of 30 to 300 Hz.

The HHG1392 is an excellent tool for measuring electromagnetic field (EMF) radiation intensity of electrical transmission equipment, power lines, air conditioners, refrigeration, computer monitors and video/audio devices.

Specifications

  • Display: 3½ digits, max indication 1999
  • Range: 200/2000 milli Gauss, 20/200 micro Tesla
  • Resolution: 0.1/1 milli Gauss, 0.01/0.1 micro Tesla
  • Measurement Axis: Single axis
  • Bandwidth: 30 to 300 Hz
  • Accuracy: +/-(3% + 3d) @ 50 or 60 Hz
  • Sampling Time: Approx. 0.4 sec
  • Power Source: Four AAA batteries (included) (only use Alkaline batteries)
  • Battery Life: 60 Hours
  • Operating Temperature Conditions: 0 to 40 °C; below 80% RH
  • Storage Conditions: -10 to 60 °C; below 70% RH
  • Dimensions: 111 H x 64 W x 34 mm D 
  • Weight: 165 g

Electromagnetic Field Tester. 3-Axis, with Data Logging

The HHG1394 Gauss meter offers a quick and reliable instrument to measure electromagnetic fields in 3 axis in the 20 to 2000 milli Gauss range or 2 to 200 micro Tesla range. The HHG1394 can measure and store up to 2000 readings for downloading into a PC with included RS232 software or operate real time for live viewing. Readings can be stored manually, at the press of a button, or automatically at a pre-set interval from 1 to 255 seconds. This meter is used to measure electromagnetic field (EMF) in the frequency band of 30 to 2000 Hz. The HHG1394 is an excellent tool for measuring electromagnetic field radiation intensity in 3 axis of electric transmission equipment, power lines, air conditioners, refrigeration, computer monitors and video/audio devices.

Specifications

  • Triple LCD Display Range: 20/200/2000 milli Gauss or 2/20/200 micro Tesla
  • Resolution: 0.01/0.1/1 milli Gauss or 0.001/0.01/0.1 micro Tesla
  • Accuracy: ±(3% + 3d) at 50 or 60Hz, ±(5% + 3d) 40Hz to 200Hz, -3db 30Hz to 2kHz
  • 20mG/2µT Range: ±(3% + 30d) 
  • Measurement Axis: Triple axis (X, Y, Z)
  • Bandwidth: 30 to 2000 Hz
  • Sample Time: Approx. 0.5 seconds
  • Memory Capacity: 2000 data sets (manual and continuous mode)
  • Auto Power Off: Approximately 15 minutes
  • Batteries: Six “AAA” (included) (only use Alkaline batteries)
  • Battery Life: 100 hours
  • Operating Conditions: 0 to 50ºC, below 80% RH
  • Storage Conditions: -10 to 60ºC, below 70% RH
  • Dimensions: 150 H x 74 W x 38 mm D 
  • Weight: 165 g

Subscribe

Subscribe to our newsletter now and stay up-to-date with new products collections, the latest and exclusive offers.

You must tick this box in order to submit your enquiry or survey response. By doing so you consent to this company gathering the personal data you have entered in your enquiry or survey. We will share this information with the product provider to enable them to contact you. Please refer to our privacy policy on this site for further information.