Fiber Optic Thermometer

The FOB100 Series comprises high-accuracy, multipurpose fiber optic thermometers with 1, 2, or 4 channels. They use an original algorithm to analyze incoming signals, measuring the temperature on each channel. The standard analog output is 0 to 10 V; 4 to 20 mA is optional. Sensors are sold separately in various cable lengths, are interchangeable, and do not require calibration.

With the optional FOB100-SOFT software for Windows (see “Accessories”), the user can download data to a PC via the RS232 communications port on the front panel. Software features include min/max alarm; full data logging functions; and bar-graph, trend-line, or statistics display.

The FOB100’s rugged enclosure and immunity to EMI/RFI interference make it ideal for demanding industrial and laboratory applications.

Portable Dew Point Monitor

This portable dew point hygrometer integrates the accuracy and reliability of the OMEGA® chilled mirror with the battery life and ruggedness required for field use. The RHB-1500-C portable chilledmirror hygrometer has all the standard features, such as drift-free NIST-traceable accuracy, low maintenance, high durability, and ease of use—in a system that is ideally suited for the demands of field use. Whether you use the RHB-1500-C as a field transfer standard or to spot-check your process air dryness or dew point, you’ll find this system provides trouble-free operation.

The RHB-1500-C is a self-contained system. Not only is no field assembly required, but also there’s no need to carry around a myriad of individual components such as control boxes, sensors, cables, pumps, and power cords. Simply attach the sample line, adjust the flow (with the integral flowmeter), and turn on the power. Within minutes you’ll be collecting field dew point data with the same chilled-mirror accuracy of a lab-standard hygrometer. And with a nominal battery life of 12 hours, the RHB-1500-C lets you collect for the entire shift or spot-check your processes for several days.

8-Channel Benchtop Digital Thermometer Data Logger

The DP9800 Series thermometer can be used in conjunction with a PC to provide accurate, versatile 8 channel thermocouple and Pt100 RTD temperature measurements, scanning and logging of measured values. It can also be used as a “stand alone” indicator/ logger and incorporates a digital backlit LCD display of measured temperature.

The built-in self-calibration facility for the DP9800-TC thermocouple model is a rapid and convenient method for on-site calibration and does not require any additional equipment other than a special, external link. Self-calibration of Pt100 ranges is equally simple and uses plug-in precision resistors. The DP9800 is designed to provide exceptional stability with high measurement resolution and represents an ideal crossover between plant practicality and laboratory performance at a very competitive price.The PC software supplied with the instrument allows control, measure and calibration functions.

Specifications

At an ambient temperature of 20°C

Input/Ranges: Thermocouple to IEC 584

  • Type J: -200 to 750°C (-328 to 1382°F)
  • Type K: -200 to 1200°C (-328 to 2192°F)
  • Type T: -200 to 350°C (-328 to 662°F)
  • Type E: -200 to 900°C (-328 to 1652°F)
  • Type N: 0 to 1300°C (32 to 2372°F)
  • Type R: 0 to 1760°C (32 to 3200°F)
  • Type S: 0 to 1760°C (32 to 3200°F)
  • Type B: 300 to 1800°C (572 to 3272°F)
  • Pt100 to IEC751, 3-Wire: -200 to 850°C (-328 to 1562°F)

Note: all inputs are non-isolated and thermocouples must be ungrounded style.

  • Accuracy: Thermocouples J, K, T, E, and N, better than ±0.1°C ±0.1% of range zero to span ±0.15% of range -100 to – 200°C (J, K, T, and E)
  • Thermocouples: R, S, and B, better than ±0.1°C ±0.15% of range
  • Linearization: ±0.05°C
  • Pt100 Range: Better than ±0.05°C ±0.1% of range
  • Zero Drift: ±0.01% of span per °C
  • Span Drift: ±0.01% of span per °C
  • Display: LCD, backlight
  • Display Resolution: Thermocouple ranges 0.1°C, Pt100 range 0.01°C
  • User Interface: Front panel key for channel number or auto-scan selection; PC software for all other functions
  • Indication: Channel number, measured temperature (°C or °F)
  • Reference Junction: Automatic, accurate reference
  • Self Calibration: User facility incorporated; the instrument auto-calibrates on every A/D cycle
  • Sensor: Open circuit upscale indication, detection and indication (independent alarms should be used for process safety if required) Ambient Operating Temperature: 0 to 50°C (32 to 122°F)
  • Storage Temperature: -20 to 70°C (-4 to 158°F)
  • Input Terminations: 8 x thermocouple, mini connectors
  • Terminal Blocks: 8 x Pt100
  • PC Interface: USB
  • Power Supply: 6 Vdc (5.5 to 9.0V) via universal mains adaptor (supplied), 120 to 250V, 50/60 Hz
  • Logging Interval: 5 second to 1 hour

Wireless Monitoring System – Low Power Transmitters

This rugged high-performance and low power consumption OMEGA® ZW-ED wireless sensor/transmitter system provides web-based monitoring temperature, humidity, and barometric pressure.

The radio is an IEEE 802.15.4 compliant transmitter operating at 2.4 GHz designed to transmit up to 1000m* (3280”) outdoor and around 100m* (328”) indoor to a ZW-REC coordinator. The ZW-REC connects directly to an Ethernet network to serve active web pages and display the data. You can monitor and record temperature, relative humidity, and barometric pressure over an Ethernet network with no special software—just your web browser.

These wireless devices are designed for demanding industrial applications indoors and harsh outdoor environments. The electronics are protected in a rugged weatherproof polycarbonate NEMA 4 (IP65) rated housing. A variety of compatible probes are available to suit your application.

* Without obstructions or interference

Specifications:

Inputs Type

Digital Probe: Temperature, Barometric Pressure, and Humidity

EXTERNAL SENSOR SPECIFICATIONS 

TEMPERATURE 

Accuracy/Range**: 

  • zTP1 (-P/-LCD/-DC/-CCELL); zTP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 10° to 85°C (±1°F for 50° to 185°F) ±1°C for -40° to 10°C and 85° to 125°C (±1.8°F for -40° to 50°F and 185° to 257°F) 
  • zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) zTHP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 5° to 45°C (±1°F for 41° to 113°F) up to 1.5°C for -40° to 5°C and 45° to 124°C (up to 2.7°F for -40° to 41°F and 113° to 255°F)
  • zBTP (-P/-LCD/-DC/-CCELL) ±0.8°C @ 20°C (±1.5°F @ 68°F) ±2°C for -40° to 85°C (±3.6°F for -40° to 185 °F) 
  • Resolution: 0.1°C 
  • Repeatablilty: ±0.1°C, for zBTHP, zTHP, zTHP2 (-P/-LCD/-DC/-CCELL), 

**Note: extended temperature ranges are for External Probes only 

Industrial Probe: 

  • SS 316 housing, 137mm x Ø16mm (5” x Ø 0.63”) for zBTP (-P/-LCD/-DC/-CCELL); zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) 
  • Short Probe, Quick Disconnect: SS 316 housing, 78mm x Ø16mm (3.1” x Ø 0.63”) for zTHP2 (-P/-LCD/-DC/-CCELL) 
  • Stick Probe: ABS tubing, 152.4 mm x Ø6.35 mm (6” x Ø 0.25”) for zTP1 (-P/-LCD/-DC/-CCELL) 
  • Lug Mounted Probe: Copper tubing, 53.4 mm x Ø 7.92mm (2.1” x Ø 0.312”); mounting hole Ø 4.72mm (Ø 0.186”) forzTP2 (-P/-LCD/-DC/-CCELL) 

Cable Dimensions and Operating Temperature: 

  • 3 m (10’) long x Ø 2.62 mm (0.103”) -80° to 200°C (-112° to 392°F) for zTHP (-P/-LCD/-DC/-CCELL); zTP1 (-P/-LCD/-DC/-CCELL); zTP2 (-P/-LCD/-DC/-CCELL) 
  • 3 m (10’) long x Ø 4.45 mm (0.175”) -55 to 105°C (-67 to 221°F) for zBTP (-P/-LCD/-DC/-CCELL); zBTHP (-P/-LCD/-DC/-CCELL)

RELATIVE HUMIDITY 

  • Accuracy/Range: zBTHP (-P/-LCD/-DC/-CCELL); zTHP (-P/-LCD/-DC/-CCELL) ±2% for 10 to 90%; ±3% for 5 to 10% and 90 to 95%; ±4% for 0 to 5% and 95 to 100% 
  • Hysteresis: ±1% RH 
  • Non-linearity: ±3% 
  • Repeatability: ±0.1% 
  • Resolution: 0.1% 

BAROMETRIC PRESSURE 

  • Accuracy/Range: zBTP (-P/-LCD/-DC/-CCELL), zBTHP (-P/-LCD/-DC/-CCELL); ±2 mbar for 10 mbar to 1100 mbar (1 KPa to 110 KPa) 
  • Resolution: 0.1 mbar 

THERMOCOUPLE INPUT (Coming Soon) 

  • Temperature Stability: 0.08°C/°C 
  • Temperature Coefficient: ±25 ppm/°C 
  • Thermocouple Cold End Tracking: 0.1°C/°C 
  • Thermocouple Lead Resistance: 100 ohm max. 
  • Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L (DIN J) 
  • Warm-Up to Rated Accuracy: 30 minutes 

ANALOG VOLTAGE & CURRENT INPUT (Coming soon) 

  • Voltage Input: Differential; bipolar; ±100 mV, ±1 V, ±10 V 
  • Input Impedance: 400 K ohm for voltage 
  • Current Input: Differential; bipolar; ±20 mA (5 Ohm load) 
  • Accuracy: ±0.1% Full Range @ 25°C 
  • Reading Rate: Periodic (1 sample/update) or continuous (20 samples/second) 
  • A/D Conversion: Sigma-Delta 
  • Resolution: 16 bits 
  • Temperature Coefficient: ±50 ppm/°C 
  • Common Mode Rejection: 105 dB 
  • Normal Mode Rejection: 98 dB 
  • Warm-Up to Rated Accuracy: 30 minutes

Environmental

Operating Conditions:

  • Base Unit: -20 to 70°C (-4 to 158°F), 90% RH non-condensing
  • CR2032 Battery: -20 to 60°C (-4 to 140°F), 90% RH non-condensing
  • Alkaline Battery: -18 to 55°C (-0.4 to 131°F), 90% RH non-condensing
  • LCD Option: -10 to 60°C (14 to 140°F), 90% RH non-condensing

Packaging

  • Enclosure Material: Polycarbonate
  • Enclosure Protection: NEMA 4 (IP65)
  • Enclosure Dimensions: 135.9 L x 82 W x 39 mm D (5.35 x 3.23 x 1.56″)

General

  • Agency Approval: ECCN 5A992, EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU, FCC ID T40JN5168M5 
  • Software: Compatible with the OMEGA® Dashboard 

Note: Because of transmission frequency regulations, the ZW series products may only be used in the United States, Canada, Europe, China, Japan, Korea, Mexico and Brazil.

Low Cost Digital Thermocouple Thermometers – Single or Dual Input

The HH11B and HH12B handheld thermometers feature Type K thermocouple inputs and are available in either single or dual input models. The HH11B is a single-input model that has auto range resolution of 0.1 or 1°. The HH12B is a dual-input meter that allows the user to display T1, T2, or øT (T1 – T2) readings with 0.1 or 1° resolution. Both models are °C/°F switchable and feature front-panel offset adjustment and maximum reading/display hold functions. Capable of measuring temperatures from -200 to 1372°C (-328 to 1999°F), these low-cost meters accept any Type K thermocouple with a mini plug.

Errors contributed by a particular thermocouple can be practically eliminated, over a limited range, by using the recessed offset adjustment on the face of the meter and an accurate temperature standard. An LED warning light indicates when an open thermocouple input situation exists.

SPECIFICATIONS

  • Measurement Range: -200 to 1372°C (-328 to 1999°F) Accuracy (Type K Chromium-Alum): ± (0.1% rdg +1°C) on -60 to 1372°C ± (0.1% rdg +2°C) on -60 to -200°C ± (0.1% rdg +2°F) on -76 to 1999°F ± (0.1% rdg +4°F) on -76 to -328°F
  • European Safety Standards: IEC-1010 and CE – EMC
  • Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0 to 18°C and 28 to 50°C
  • Display: 31.2 digit LCD, maximum reading 1999
  • Sampling Rate: 2.5/s
  • Battery: 9 V (included)
  • Battery Life: 200 hours typical
  • Dimensions: 210 H x 65 W x 33 mm D (8.3 x 2.4 x 1.4″)

Pt100 RTD Thermometer, Handheld, High Accuracy

The Pt100 RTD handheld thermometer is a high accuracy device, capable of reading temperatures up to 850.0°C (1562.0 °F).

Standard Features:

  • Min./Max. Memory: Memorising of max. and min. values.
  • Hold Function: Freeze the current display values at the push of a button.
  • Auto-Off-Function: 1…120min (can also be deactivated).
  • Offset and Slope Input: offset and scale factor can be entered digitally

GMH3570 Additional Features:

Alarm: 3 different alarm settings:

  •     Off: alarm function not activated
  •     On: visual alarm via display, integrated buzzer and interface
  •     No Sound: alarm via display and interface

Min./Max. Alarm: the measuring value is constantly monitored and the alarm triggered if it goes 

outside the min./max. limits set.

Logger functions:

  • Real-time clock: clock with date and year
  • Manual: 99 data sets (data recall via keyboard or interface)
  • Cycle: 16,200 data sets (data recall via interface)
  • Adjustable cycle time: 1sec. … 1h. Logger start and stop via the keyboard or interface.
  • Easy to use read-out and display software (GSOFT3050) available as an option.

Specifications

  • Measuring Range: -199.99 … +199.99°C or -200.0 … + 850.0°C (-199.99 … +199.99°F or -328.0 … +1562.0 °F)
  • Resolution: 0.01°C or 0.1°C; 0.01°F or 0.1 °F
  • Auto-Range: automatically or manually select the measuring range.
  • Accuracy (±1 digit) (@ 25°C):
  • ≤ ± 0.03°C for -199.99 to +199.99°C range
  • ≤ ± 0.1°C for -200.0 to +850.0°C range
  • GMH3750 additionally supports a 50-point user defined curve.
  • Temperature Drift: ≤ 0.002 °C/K
  • Probe: Pt100, 4-wire, DIN EN 60751. Probe connection via 4-pin miniature DIN-plug
  • Operating Temperature: -25 to +50°C
  • Relative Humidity: 0 to +95%RH. (non-condensing)
  • Storage Temperature: -25 to +70°C
  • Display: two 4½ digit LCDs (12.4mm or 7mm high), with additional symbols.
  • Keypad: 6 membrane keys
  • Output: 3.5 mm stereo jack socket, choice between serial interface or analogue output
  • Serial Interface: direct connection to RS232 or USB interface of a PC via electrically isolated interface adapter GRS3100/USB3100.
  • Analogue Output: 0…1V, adjustable (resolution 13bit, accuracy 0.05% at nom. temp.)
  • Power Supply: 9V-battery (included) as well as additional d.c. connector for external 10.5- 12V direct voltage supply. (suitable power supply: GMH37XX-PSU)
  • Low Battery Warning: ‘ bAt ‘
  • Power Consumption: approx. 1 mA
  • Dimensions: 142 x 71 x 26 mm (H x W x D)
  • Housing: Impact resistant ABS plastic housing, membrane keypad. Front face IP65, integral stand/belt-clip.
  • Weight: approx. 155 g

Dual Input, Datalogger/Thermometer. RS232 or USB

The OMEGA® HH506RA is a low cost, feature-packed, portable, digital thermometer that measures K, J, R, S, T, E and N thermocouples. The unit has a manual save mode where up to 128 T1/T2 readings can be saved at the press of a button.

Datalogging mode allows up to 1024 data values to be recorded automatically at preset intervals between 1 second and 24 hours. The meter also features MAX, MIN, AVG, REL, and HOLD functions. 

The HH506A has no data output, logged values may be recalled through the display only. 

SPECIFICATIONS 

Temperature Range: 

  • K Type: (0.1°, 1° for above 2000°F) -200 to 1372°C (-328 to 2501°F) 
  • J Type: (0.1°, 1° for above 2000°F) -210 to 1200°C (-346 to 2192°F) 
  • T Type: (0.1°) -200 to 400°C (-328 to 752°F) 
  • E Type: (0.1°) -210 to 1000°C (-346 to 1832°F) 
  • R Type: (1°) 0 to 1767°C (32 to 3212°F) 
  • S Type: (1°) 0 to 1767°C (32 to 3212°F) 
  • N Type: (0.1°, 1° for above 2000°F) -50 to 1300°C (-58 to 2372°F) 

According to temperature standard ITS-90 

Accuracy: 

  • K/J/T/E Type: ±(0.05% rdg + 0.3°C) on -50 to 1370°C. ±(0.05% rdg + 0.7°C) on -50 to -210°C. ±(0.05% rdg + 0.6°F) on -58 to 2501°F. ±(0.05% rdg + 1.4°F) on -58 to -346°F 
  • N Type: ±(0.05% rdg + 0.8°C) on -50 to 0°C. ±(0.05% rdg + 0.4°C) on 0 to 1300°C. ±(0.05% rdg + 1.6°F) on -58 to 32°F. ±(0.05% rdg + 0.8°F) on 32 to 2372°F 
  • R/S Type: ±(0.05% rdg + 2°C) on 0 to 1767°C. ±(0.05% rdg + 4°F) on 32 to 3212°F 

Resolution: 0.1°C/1°C (0.1°F/1°F) 

Power: 9 V battery (included) 

Datalogger Capacity: 

  • Save Data: 128 samples with time stamp 
  • Datalogger: 1024 data capacity(interval 1 sec to 23:59:59)

OMEGASCOPE® High Quality Handheld Infrared Thermometer Series. Analogue and RS232 Outputs Available on Some Models

With a combination of powerful features, the new portable and rugged OS530 series infrared thermometers offer solutions for many non-contact temperature measurement applications. Emissivity adjustable in 0.01 increments, the OS530 series provides versatility when measuring a variety of surfaces.

A custom backlit LCD display provides dual digital display of both current and max, min, diff or average temperatures simultaneously. This provides the user with more information at a glance. Built-in laser sighting creates a 12-point circle which clearly indicates the target area being measured.

The OS530 Series also features a high alarm setpoint, providing both audible and visual indication of the alarm status. The standard 1 mV per degree analog output allows interfacing with data acquisition equipment, including chart recorders, dataloggers and computers. PLease review PDF file (link below) for complete product specifications

All Models Feature: Adjustable Emissivity, Backlit Dual Display, Differential Temperature, Min/Max Temperature, Average Temperature, High Alarm, Audible Buzzer & Indicator, Analogue Output (1mV/Deg), Laser Sight (Built-In), Trigger Lock, Last Temperature Recall. OS532 Adds Thermocouple Input, OS533 Adds Low Alarm, Ambient Target Temperature Compensation, RS-232 Outpput, Thermoucouple Input. OS534 Adds all of the OS533 Features plus Data Storage. 

Also Available – Built-In Distance Measurement OMEGASCOPE® OS530E-DM Series of High Performance, General Purpose, and High Resolution Infrared Pyrometers.

Caution: This product and all in the series are not for use in medical evaluations. These products cannot be used to measure body temperature. They are meant for industrial and scientific purposes. 

Handheld Calibrator Multi-Functional

Easy-to-hold vertical body is designed to make it intuitively easy to operate, as individual functions are accessed directly by pressing assigned keys. The main body case (sold separately) is designed to make it easy to hold the CA150 in one hand.

Simultaneous Source and Measurement for Process Devices

In conventional calibration applications, multiple devices such as a standard generator, dial resistor and multimeter were required. Now with a single CA150 unit, it is possible to perform operation check at regular inspection and maintenance of thermocouples, RTDs and instruments, as well as maintenance and equipment diagnosis of process devices such as transmitters, thermostats and signal converters.

Loop Power Supply Function

It is possible to measure generated current signals while supplying loop power 24 Vdc from a two-wire type transmitter (up to 22 mA DC).

Highly Accurate and Multi-Functional Source and Measurement

High Accuracy: 0.02% for the source unit and 0.02% for the measurement unit Source and Measurement Functions: DCV voltage, DC mA, ohm, Frequency and temperature (thermocouple, RTD) and 24 Vdc power supply function for transmitters

Memory Functions: Setting Memory

This function saves/loads setting conditions. Up to 21 data items can be stored. Settings for (source/ measurement) functions, ranges, generated values/measured values as well as setting mode conditions can be stored.

Data Memory

This function saves source and measure values displayed. Up to 100 data items can be stored. Storage date/time, (source/ measurement) functions, ranges and generated values/measured values can be stored. Stored data can be checked on the display of the main unit as well as via communication.

Multifunction Calibrator

The CL310 documenting multi-function calibrator delivers a feature set unmatched in high accuracy, hand-held calibrators in its price range. The CL310 delivers functions and accuracy associated with fixed installation, laboratory instruments, and has everything needed for virtually any calibration task. What makes this versatile calibrator best in class is the ability to fully document any calibration easily while performing the normal job. Software is included. Some functions will require a Microsoft Excel-compatibility.

CL310 can also measure and source thermocouples, RTDs, current, voltage, frequency, and it can source pulse trains. It has a communications port for pressure modules and an isolated mA/V readback circuit. Arrow keys, direct numeric keypad entry, and three softwaredriven function buttons combine with a large, backlit, menu-driven graphics display to provide a highly intuitive yet powerful interface. A built-in 250 Ù resistor for Hart® compatibility; compatibility with smart transmitters and PLCs, full fuseless protection, and a serial communications port for control using ASCII commands are additional features that make the CL310 indispensable for calibration tasks. This product is battery operated.

Measuring Pressure With a PCL-PMA pressure module adaptor, the CL310 will work with all OMEGA PCL-PM pressure modules. 

SPECIFICATIONS (23 ±5°C unless otherwise noted)

Voltage:

  • Source: 0.000 to 20.000 Vdc
  • Read: Isolated: 0.000 to 30.000 Vdc
  • Read: Non-Isolated: 0.000 to 20.000 Vdc

Thermocouple mV:

  • Read/Source: -10.000 to 75.000 mV

Current (mA):

  • Source: 0.000 to 24.000 mA
  • Read: Isolated: 0.000 to 24.000 mA
  • Read: Non-Isolated: 0.000 to 24.000 mA

Frequency (1 to 20V Selectable Amplitude):

  • CPM Source/Read: 2.0 to 600.0 cpm
  • Hz Source/Read: 1.0 to 1000.0 Hz
  • kHz Source/Read: 1.0 to 10.00 kHz

Pulse (Source Only 1 to 20V; Selectable Amplitude):

  • Pulses: 1 to 30,000; 2 cpm to 10 kHz

Ohms:

  • Source: 5.0 to 4000.0Ω
  • Read: 0.00 to 4000.0Ω

Thermocouple Range Read and Source:

  • Type J: -200.0 to 1200.0°C (-328 to 2192°F)
  • Type K: -200.0 to 1370.0°C (-328 to 2498°F)
  • Type T: -200.0 to 400.0°C (-328 to 752°F)
  • Type E: -200.0 to 950.0°C (-328 to 1742°F)
  • Type R: -20.0 to 1750.0°C (-4 to 3182°F)
  • Type S: -20.0 to 1750.0°C (-4 to 3182°F)
  • Type B: 600.0 to 1800.0°C (1112 to 3272°F)
  • Type C: 0 to 2316.0°C (32 to 4201°F)
  • Type XK: -200.0 to 800.0°C (-328 to 1472°F)
  • Type BP: 0 to 2500.0°C (32 to 4532°F)
  • Type L: -200.0 to 900.0°C (-328 to 1652°F)
  • Type U: -200.0 to 400.0°C (-328 to 752°F)
  • Type N: -200.0 to 1300.0°C (-328 to 2372°F)

RTD Range Read and Source:

  • Ni120 (672): -80.0 to 260.0°C (-112 to 500°F)
  • Pt100 (385): -200.0 to 800.0°C (-328 to 1472°F)
  • Pt100 (3926): -200.0 to 630.0°C (-328 to 1166°F)
  • Pt100 (3916): -200.0 to 630.0°C (-328 to 1166°F)
  • Pt200 (385): -200.0 to 630.0°C (-328 to 1166°F)
  • Pt500 (385): -200.0 to 630.0°C (-328 to 1166°F)
  • Pt1000 (385): -200.0 to 630.0°C (-328 to 1166°F)
  • Cu10: -100.0 to 260.0°C (-148 to 500°F)
  • YSI400: 15.00 to 50.00°C (59 to 122°F)
  • Cu50: -180.0 to 200.0°C (-292 to 392°F)
  • Cu100: -180.0 to 200.0°C (-292 to 392°F)
  • Pt385-10: -200.0 to 800.0°C (-328 to 1472°F)
  • Pt385-50: -200.0 to 800.0°C (-328 to 1472°F)

Accuracy

  • Voltage: ±0.015% of reading, ±2 mV
  • Thermocouple: mV ±0.02% of reading, ±10 µV
  • Thermocouple Errors (Typical at 100°C) (In °C; Add 0.2 for Cold-Junction Compensation Error)
  • Type J: 0.2°C (0.4°F) 
  • Type K: 0.3°C (0.5°F)
  • Type T: 0.2°C (0.4°F)
  • Type B: 1.2°C (2.2°F)
  • Type S: 1.2°C (2.2°F) 
  • Type XK: 0.2°C (0.4°F)
  • Type C: 0.6°C (1.6°F) 
  • Type L: 0.2°C (0.4°F)
  • Type BP: 0.9°C (34°F) 
  • Type N: 0.4°C (0.7°F)
  • Type U: 0.25°C (0.5°F) 

RTD Read/Source:

  • Ni120 (672): 0.06°C (0.11°F) 
  • Pt100 (385): 0.13°C (0.23°F)
  • Pt100 (3926): 0.13°C (0.23°F) 
  • Pt100 (3916): 0.13°C (0.23°F)
  • Pt200 (385): 0.45°C (0.81°F) 
  • Pt500 (385): 0.21°C (0.38°F)
  • Pt1000 (385): 0.14°C (0.75°F) 
  • Cu10: 0.82°C (1.48°F)
  • YSI400: 0.05°C (0.09°F) 
  • Cu50: 0.20°C (0.36°F)
  • Cu100: 0.13°C (0.23°F) 
  • Pt385-10: 0.84°C (2.16°F)
  • Pt385-50: 0.21°C (0.38°F) 

Read/Source:

  • Current (mA): ±0.015% of reading, ±2 µA/±0.015% of reading, ±2 µA
  • CPM: ±0.05% of reading, ±0.1
  • Hz: ±0.05% of reading, ±0.1 Hz
  • kHz: ±0.05% of reading, ±0.01 kHz/±0.125% of reading

Ohms (Works with All Pulsed Transmitters Down to 5 ms):

  • 5 to 400 Ohms Range: ±0.015% of reading ±0.03Ω/ ±0.015% of reading ±0.1Ω
  • 400 to 1500 Ohms Range: ±0.015% of reading ±0.3Ω
  • 1500 to 4000 Ohms Range: ±0.015% of reading ±0.3Ω

Environmental

  • Operating Temperature: -10 to 50°C (14 to 122°F)
  • Storage Temperature: -20 to 70°C(-4 to 158°F)
  • Stability: ±0.005% of reading/°C (outside of 23°C ±5°C)
  • Power Requirement: 6 Vdc
  • Batteries: 4 “AA” alkaline (included) or optional rechargeable

Mechanical

  • Dimensions: 220.9 H x 106.6 W x 58.4 mm D (8.7 x 4.2 x 2.3″)
  • Weight: 863 g (30.5 oz)

Subscribe

Subscribe to our newsletter now and stay up-to-date with new products collections, the latest and exclusive offers.

You must tick this box in order to submit your enquiry or survey response. By doing so you consent to this company gathering the personal data you have entered in your enquiry or survey. We will share this information with the product provider to enable them to contact you. Please refer to our privacy policy on this site for further information.