Designed for monitoring of oxygen content within flue or stack gases, the GAP has relays, analog and modbus outputs along with pressure and temperature compensation making it a complete analyzer for combustion optimization and burner/boiler trim applications.
A compact zirconium-oxide analyzer to efficiently monitor excess air in combustion processes. The probe is manufactured from 316 stainless steel and can handle sample temperatures up to 700°C with an insertion length of 435mm (17.126″). The sample is extracted to the sensor chamber and returned to the flue via the Pitot effect, so there is no need for instrument air. The analyzer operates without the need for an air reference.
Designed with ease of maintenance in mind. The GAP’s user replaceable sensor can be cleaned or replaced in seconds.
The Zirconia Oxygen Sensor System offers a complete solution, removing the need for customers to develop their own electronics. Frequently used in combustion control systems, burning coal, oil, gas and biomass and in oxygen generation systems.
The Zirconia Oxygen Sensor System consists of SST’s fast response (<4s T90) zirconium dioxide (ZrO₂) screw fit sensor in conjunction with the OXY-LC oxygen sensor interface board.
The system employs a well proven, zirconium dioxide element at its heart and, due to its innovative design, does not require a reference gas. This, along with its rugged stainless steel construction means the sensor can be used in extreme temperatures and aggressive environments.
These oxygen sensors use a unique closed loop measurement system. While the sensor continuously measures the oxygen level, a heartbeat signal is also generated, providing an immediate warning of any failures.
The sensor is housed in a short probe with an M18x1.5mm thread, making installation quick and easy. The oxygen sensor can operate in temperatures ranging from -100°C to 250°C and has a lifetime of up to 10 years (depending on the application).
When connected to the OXY-LC interface board, the zirconia oxygen sensor can measure oxygen concentrations of 0.1% to 25% and 0.1% to 100%.
Online store is temporarily unavailable – please contact us to buy this product.
The OXY-Flex Oxygen Analyzer is suitable for measuring in oxygen closed systems, such as ventilation pipes and boiler exhaust flues.
The OXY-Flex Oxygen Analyzer is designed to measure the oxygen concentration in air or gas mixtures with temperatures of -100 to 400⁰C. The oxygen analyzer employs a well proven, small zirconium dioxide based element at its heart and due to its innovative design does not require a reference gas. The oxygen sensor element is mounted in the tip of the stainless steel probe and is protected by a sintered stainless steel cap.
The OXY-Flex Oxygen Analyzer uses a unique closed loop measurement system. While the sensor continuously measures the oxygen level, a heartbeat signal is also generated providing an immediate warning of any failures.
The OXY-Flex can be configured to output measuring ranges of 0-25% O₂ or 0-100% O₂. The entire measurement range is linear in both cases. The outputs can be configured to either 4-20mA and 0-10Vdc outputs or an RS232 serial communications interface.
Typical applications include; combustion control of industrial boilers, burning oil, gas, coal or biomass; incubators; composting probes and welding equipment.