Dräger Sampling Tubes and Systems

The Dräger Sampling Tubes and Systems are very reliable in use even with complex compounds and mixtures of substances.

Benefits

Accurate and reliable results

  • The hazardous substances in the air are collected using a suitable medium – such as activated charcoal, silica gel or molecular sieves. The sample is then analyzed in a laboratory with the aid of instrumental analysis. The sampling process is conducted either actively with a manual Dräger accuro or automatic Dräger-Tube pump X-act 5000, or passively via a diffusion sampler.

Suitable for complex cases

  • The Dräger Sampling Tubes and Systems allow to identify and measure different substances even under difficult conditions. This applies especially to very complex mixtures of substances or cases in which several similar substances are present at the same time.

Advantages of passive sampling

  • Low price since no additional sampling equipment is required
  • Long-term sampling does not require any preparation of the room
  • Low determination and detection limits
  • Fluctuations of concentration are integrated into the measurement result
  • Overview measurements as well as surveillance of limit values

Advantages of active sampling

  • Accumulation of substances in large amount of air within short time
  • Low determination and detection limits

Dräger X-act® 5000

The automatic tube pump Dräger X-act 5000 is the first all-in-one solution designed for measurements with Dräger short-term tubes and for sampling tubes and systems. Ease of operation and a high degree of reliability compliment the measurement and sampling of gases, vapors and aerosols.

Benefits

Versatile and robust

  • The Dräger X-act 5000 introduces a new era of gas measurement: Only one device is necessary for measuring and sampling. The automatic tube pump is compatible with Dräger short-term tubes as well as sampling tubes and systems.
  • The robust housing supports the use of the pump to perform the daily measuring tasks under tough conditions. The IS approved (pending) Dräger X-act 5000 can be used for confined space applications and in explosive gas atmospheres.

New pump concept

  • The key principle is the ability to provide the required flow characteristics of the Dräger Short-term Tubes, while also providing the option to be used with Sampling Tubes and Systems requiring constant flow. Compared to the Dräger accuro hand pump, this new concept reduces the average measurement time of the Dräger Short-term Tubes in case of a high number of strokes. The internal pump is also designed to use extension hoses up to a length of 30 meters (98 ft.).

Simplicity of operation

  • The handling of gases, vapors and aerosols has never been easier. The automatic tube pump Dräger X-act 5000 directs the air to be measured through the appropriate Dräger-Tubes effortlessly. It is comfortably carried with one hand or using the shoulder strap and is easily operated, even wearing protective gloves. A simple and intuitive menu structure provides the user efficient operation with just a few button presses. Using the password-protected menu repetitive operating modes can be set.

Automatic transfer of measurement parameters

  • A barcode printed on the label on the backside of a Dräger Short-term Tube box contains all relevant measurement parameters. Simply sliding the barcode over the barcode reader of the pump, automatically transfers the name of the substance to be measured, the number of strokes, and the measuring range to the display. The required steps to carry out the measurement are simplified with the Dräger X-act 5000 and the possibility of making an error is reduced to a minimum.

Measurement in technical gases

  • To evaluate measurements in technical gases, the properties of the technical gas must be taken into consideration. Technical gases have a different viscosity than ambient air. Therefore, the flow of the pump must be set accordingly. Following the operating steps in the mode „Measurement in Technical Gases“, the Dräger X-act 5000 will automatically be adjusted to the required flow parameter and the measurement result can be read directly.

Direct settings for sampling

  • Depending on the Sampling Tubes or Systems, the required parameters for the test can be set directly, without the need for an external flowmeter. The Dräger X-act 5000 automatically adjusts the flowrate. After setting the sampling time the pump can immediately be started. At the end of the measurement the pump will stop automatically. The set data, the elapsed time and the pumped volume will be indicated on the display.

Dräger X-am® 2500

The Dräger X-am® 2500 was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2, CO, NO2, SO2 and H2S. Reliable and fully mature measuring technology, durable sensors and easy handling guarantee a high degree of safety with extremely low operating costs.

Benefits

Durable electrochemical sensors

  • Fully developed, high performance Dräger sensors in an extra small format for CO, H2S, O2, SO2 and NO2 gases enable safe use in industry, mining and in refineries. The impressive hydrogen sulphide sensor has a high resolution, so it can reliably measure even very low workplace limits. The non-consumptive and lead-free sensor for oxygen is characterized by an especially long service life of more than 5 years. Our CO and H2S sensors also have this long service life expectation, so they contribute to especially low operating costs.

Poison resistant ex sensor

  • The innovative, catalytic Ex sensor is im- pressive due to its high resistance to silicone and hydrogen sulphide. Together with the high degree of drift stability, this resistance enables an extraordinarily long service life of more than 4 years. Its sensitivity with regard to flammable gases and vapours is tested in accordance with the technical approval for measuring IEC/EN 60079-29-1 from methane to nonane. This approval also demonstrates the suitability of this instrument for primary explosion protection, e.g. for use in refineries and in the chemical industry.

Maximum safety

  • The Dräger X-am 2500 has Ex approval for zone 0, so it is clearly designed for very high user safety in areas subject to explosion hazard. The functional design ensures that gas can enter from above and from the side – even if the instrument is inside a pocket or if the front gas entry is accidentally covered.

Maintenance: fast, easy, inexpensive

  • From functional test to complete documentation, users have access to practical solutions that provide safety for implementation at any time. The Dräger Bump Test Station, which does not require a local power source, and the automatic Dräger X-dock testing and calibration station for comprehensive equipment management are ideal system additions that save time and effort. Together with the Dräger X-dock, the high quality Dräger sensors enable quick bump tests of 8 to 15 seconds1 with very low gas consumption. This significantly reduces your equipment operating costs.

With standard sensors: CH4, O2, CO, H2S

Diffusion or pump

  • For clearance measurements for tanks and shafts or when searching for leaks, an optional external pump with a hose up to 30 m long is the optimum solution. The pump starts automatically when the measuring instrument is inserted in the external pump. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.

Ergonomic and robust

  • Thanks to its low weight and ergonomic design, the Dräger X-am 2500 offers a high degree of wearing comfort. The practical 2008two button control panel and easy menu navigation allow the instrument to be used intuitively, despite its comprehensive functionality. The integrated protective rubber coating and sensors that are not sensitive to shock provide additional safety in case of impacts or vibrations. More-over, the Dräger X-am 2500 is not sensitive to electromagnetic radiation, e.g. from wireless devices. The Dräger X-am 2500 is water and dust resistant in accordance with protection class IP67, so it remains fully functional even if it falls into the water.

Reliable power supply

  • The Dräger X-am 2500 can operate with either alkaline batteries or with rechargeable NiMH batteries. This enables a reliable power supply for more than 12 hours, and with the high capacity battery pack more than 13 hours. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without Ex sensor is typically more than 250 hours.

Dräger MSI EM200

Measure differential pressure, temperatures and a wide range of gas concentrations with high precision: the Dräger MSI EM200 flue gas analyzer allows you to do just this. Dräger designed the device for measuring, testing and installing gas, oil and solid fuel heating systems. The MSI EM200 has been tested in accordance with EN 50379-1 and EN 50379-2, as well as to ensure that it meets the requirements asked of measuring devices, in accordance with RdSchr. BMU v. 31.1.1997 and ZIV KÜO. The device is, therefore, approved for official measurements.

Benefits

Extra protection for all components

  • All components are fixed through the EPP inner casing and are excellently protected by PU foam in an external casing. This method results in a construction that is particularly resistant to impact and shock.

Measurements

  • Oxygen
  • Combustion air temperature
  • Flue gas temperature
  • Fine drafts
  • Drafts
  • Differential pressure
  • Carbon monoxide and
  • NO, NO2 or SO2, depending on the version

Guaranteed long-life cycle

  • The oxygen sensor is particularly long-lasting.

Properties

  • Menu-controlled data memory
  • Option for reading digital automatic firing devices with Dräger MSI Dual BCI-S or Dräger MSI Smart BCI
  • Automatic pump stop in case CO measurement range is exceeded
  • Electrochemical sensors to measure gas concentrations
  • CO measuring range 8000 ppm (30.000 ppm optional)

Dräger Short-term Tubes

Tried and tested a million times: Worldwide, the Dräger Short-term Tubes have proven to be a very cost-effective and reliable method for the measurement of gases. Decreasing occupational exposure values, special customer requirements and new legal regulations made it necessary to develop even more sensitive Dräger-Tubes.

 

Benefits

Quick and targeted measurements

  • For spot measurement more than 500 different gases can be detected. The measurement usually takes between 5 seconds and 15 minutes. Furthermore, the easy-to-use Dräger-Tubes have already been calibrated and form a complementary unit with the Dräger-Tube pumps.

Easy handling

  • The Short-term Tubes are used either manually with the Dräger-Tube pump accuro or automatically with the Dräger X-act 5000. The results can then be read directly at the end of the measurement process.

Fields of application

  • Air examinations at the workplace in the range of legal limit values
    technical gas analysis in the areas of emission concentrations / immission concentrations
    measurements of compressed air / compressed gases

Flexible use

  • A large number of different gases and vapors can be measured by the Short-term Tubes. These tubes are used e.g. for the determination of concentration peaks, the measurement of exposures in the inhalation area, the determination of possible leakages as well as for the analysis of air in sewers, shafts, tanks or other confined spaces.

 

Dräger MSI P3

A choice of three: The Dräger MSI P3 pressure measurement device comes with a measurement range up to 199.9 mbar, 1.5 bar, or 4.99 bar.

Benefits

Tightness test, in accordance with DVGW-TRGI 2008

  • Using the Dräger MSI P3, tightness tests can be performed with 150 mbar, in accordance with the conditions of the new DVGW-TRGI 2008.

Measurements

  • The device is intended for the following measurements:
    • Chimney draft (negative / positive pressure)
    • Pressure measurements on gas fired units (supply pressure / flow pressure / nozzle pressure)
    • Tightness tests

Properties

  • Practical one-key operation
  • Ready for use immediately
  • Digital display
  • Fully-automatic selection of measurement range
  • Configuration to hPa or mbar
  • Battery or rechargeable battery operation

Dräger Bio-Check Formaldehyde

Dräger-Bio-Check F has been tested by a number of organisations and is suitable for guideline formaldehyde measurements – especially for if the user is unskilled in testing.

Instructions for use:

  • Press start button
  • Position instrument in room
  • After 2 hours, check results against enclosed colour comparison strip

Dräger Bio-Check® Allergen Control

Exposure to the allergens of house dust mites is one of the most common causes of allergies. Dräger Bio-Check® Allergen Control quickly reveals the presence of these allergens.

Description

The Dräger-Bio-Check Allergen Control rapid-test allows the user to conduct an on-site analysis of house dust mite allergens. The table supplied with Dräger-Bio-Check Allergen Control groups the exposure levels into categories based on the scientific limit values for house dust allergens.

Instructions for use:

  • Remove test from packaging
  • Wipe the Dräger-Bio-Check Allergen Control for one minute over the surface of the object in question (e.g. mattress, upholstery, carpet) to collect dust
  • Drip the solution supplied with the product onto the sample.

After 10 minutes the colour change will reveal the allergen concentration.

Calibration gas and accessories

Calibration of equipment will ensure safe operation and functionality of equipment and will also meet with the applicable regulations and codes of practice. Various calibration options are available to provide this facility.

Benefits

  • Single gas and mixtures of reliable quality

Dräger provides single gases and gas mixtures of reliable, constant quality. These are available in a range of different size cylinders.

  • Tailor-made for Dräger gas measuring devices

The Dräger calibration gases are specifically tailored to meet the requirements of the range of gas measuring devices.

  • Recyclable cylinders

The gases are supplied in small, light and recyclable disposable cylinders. Therefore, calibration tasks and function tests can easily be carried out in the workshop or on site.

Dräger MSI P7

Fit for the new DVGW-TRGI 2008: The Dräger MSI P7 provides several methods for you to test pipelines and containers that are filled with gas or air. The device has been tested in accordance with DVGW VP 952 and is the ideal tool for working in compliance with the new DVGW-TRGI 2008. Automatic absolute pressure and temperature compensation guarantee precise measurements.

Benefits

Gas safety test in just 10 to 15 minutes!

  • The Dräger MSI standard leak procedure is particularly quick and easy for the user. There is no need to disassemble a gas meter or to connect a container with gas to the gas line. The MSI P7 uses the changes in pressure measured with and without the standard leak to determine the leakage rate and volume in the gas line in just 10 to 15 minutes! The serviceability check (gas safety check) meets the technical conditions of the new DVGW-TRGI 2008.

Load test, in accordance with DVGW-TRGI 2008

  • In the load test (previously the preliminary test), the pressure in the gas line is increased to 1 bar. The measurement results can be displayed, printed or saved.

Leak test, in accordance with DVGW-TRGI 2008

  • The leak test is fully automatic with the MSI P7. In addition, the gas line to be tested is connected to the MSI P7 via just one pressure measurement hose. The pressure in the gas line to be tested is automatically increased to 150 mbar (previously 110 mbar) by the measurement system, in accordance with the new DVGW-TRGI 2008. The stabilization and measurement times correspond to DVGW TRGI G 600, chapter 5.6.4.2.

At a glance

  • Gas safety test in just 10 to 15 minutes
  • Fully automatic leak rate measurement
  • No need to demount the gas meter or establish a connection to fill external containers with gas
  • Automatic measurement of pipeline volume
  • Leak test with 150 mbar, including fully automatic pressure restoration
  • Documentation of measurement results via infrared printer and PC
  • Tests comply with new technical conditions of the DVGW-TRGI 2008.
  • DVGW-approved (DVGW No.: DG-4805BS0029) Serviceability test for natural gas, propane and air

Subscribe

Subscribe to our newsletter now and stay up-to-date with new products collections, the latest and exclusive offers.

You must tick this box in order to submit your enquiry or survey response. By doing so you consent to this company gathering the personal data you have entered in your enquiry or survey. We will share this information with the product provider to enable them to contact you. Please refer to our privacy policy on this site for further information.

I accept the terms and conditions.


Get the newsletter - Keep up to date with Health, Safety & Environmental monitoring products from across the globe with our free newsletter